Skip to content
EvidenceHelixEvidenceLib · Scientific Encyclopedia
⌘ K

Scientific library

EvidenceLib encyclopediaAll articles A–Z2,100Open textbooks2Cancer study catalog458How it is made

My workspace this browser

Saved pages0Notes & annotations0

Recently viewed

Explore by field

Cancer and Oncology107Genetics and Genomics95Neuroscience110Cardiovascular Medicine105Immunology90Pharmacology99Molecular Biology100Infectious Diseases102Rare and Inherited Diseases106Clinical Research98Anatomy and Physiology542Drugs and Chemicals546
Plans & pricingCompare EvidenceHelix workspace plans
Library›EvidenceLib›Cardiovascular Medicine›Blood Flow Velocity
Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

Research reading room

Blood Flow Velocity

Cardiovascular Medicine · NLM MeSH · updated 2026-10-29 · version 1

Citations verified against PubMedNot yet clinician-reviewed10 referencesApproximately 6 min read

A value equal to the total volume flow divided by the cross-sectional area of the vascular bed.

Table of Contents

1. Definition2. Research landscape3. Reading the evidence4. Open-access studies5. Key reviews6. References7. About this article

Definition and research guide

This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.

Content available: 4 complete abstracts (1,176 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.

Definition

A value equal to the total volume flow divided by the cross-sectional area of the vascular bed.

Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.

Also known as: Blood Flow Velocities; Flow Velocities, Blood; Flow Velocity, Blood; Velocities, Blood Flow; Velocity, Blood Flow.

Where it fits in the MeSH classification

Broader topics
Diagnostic Techniques, Cardiovascular; Hemorheology

Research landscape

PubMed indexes 62,016 records tagged with the MeSH heading “Blood Flow Velocity” (counts retrieved 2026-10-29). 4,348 of them (7.0%) were published from 2020 onward, and the busiest period so far is through 1999 with 29,385 records.

Reviews account for 3,201 records (5.2%) and meta-analyses for 106. Randomized controlled trials number 1,907 (3.1%) as a share of all records on the topic.

PubMed records by publication periodthrough 1999: 29,385 records; 2000-2009: 15,477 records; 2010-2019: 12,806 records; 2020 onward: 4,348 records29,385through 199915,4772000-200912,8062010-20194,3482020 onward
Records in PubMed indexed with this heading, by publication period. Real counts from NCBI E-utilities; the final period covers only part of the current year. Volume reflects how much has been published, not how strong the evidence is.
Show the data
PeriodRecords
through 199929,385
2000-200915,477
2010-201912,806
2020 onward4,348
Share of records by publication typeReviews: 5.2 percent; Meta-analyses: 0.2 percent; Randomized controlled trials: 3.1 percentReviews5.2% (3,201)Meta-analyses0.2% (106)Randomized controlled trials3.1% (1,907)
Share of all PubMed records on this heading that carry each publication type. Types overlap with other records, so the shares do not sum to 100%.
Publication-type chart data
Publication types among 62,016 PubMed records
TypeRecordsShare
Reviews3,2015.2%
Meta-analyses1060.2%
Randomized controlled trials1,9073.1%

Method: PubMed query "Blood Flow Velocity"[MeSH Terms] with publication-type and date filters, retrieved 2026-10-29.

Reading the evidence in cardiovascular medicine

Cardiovascular medicine has an unusually large body of randomized trials, so the type of outcome matters: hard clinical events such as death, heart attack and stroke carry more weight than changes in blood pressure, cholesterol or imaging markers that only predict risk. Observational studies can show associations but are confounded by age, lifestyle and other illness. Check whether a result is about prevention or treatment, the baseline risk of participants, and the absolute rather than only the relative size of any benefit.

Evidence from open-access studies

These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.

Study comparison — selected abstracts, not a systematic review
Study / authorsYearSource label / designEurope PMC citationsLicence / source
Assessment of Jugular Venous Blood Flow Stasis and Thrombosis During Spaceflight
Marshall-Goebel K, Laurie SS, Alferova IV, Arbeille P, Auñón-Chancellor SM, Ebert DJ, et al.
2019Research article
Design not recorded in structured metadata
185cc by
PMID 31722025 · DOI · PMC6902784
TWIST1 Integrates Endothelial Responses to Flow in Vascular Dysfunction and Atherosclerosis
Mahmoud MM, Kim HR, Xing R, Hsiao S, Mammoto A, Chen J, et al.
2016Research article
Design not recorded in structured metadata
132cc by
PMID 27245171 · DOI · PMC4959828
Regulation of blood flow and volume exchange across the microcirculation
Jacob M, Chappell D, Becker BF
2016Review article
Design not recorded in structured metadata
103cc by
PMID 27765054 · DOI · PMC5073467
Comparative Assessment of Retinal Blood Flow Velocity Changes Following Brimonidine and Brinzolamide Administration Using Retinal Function Imaging
Enz TJ, Bittner M, Tribble JR, Williams PA, Thiel MA, Schmid MK, et al.
2022Randomized controlled trial
Design not recorded in structured metadata
4cc by
PMID 35103799 · DOI · PMC8819484

Assessment of Jugular Venous Blood Flow Stasis and Thrombosis During Spaceflight [1]

Research article Marshall-Goebel K, Laurie SS, Alferova IV, Arbeille P, Auñón-Chancellor SM, Ebert DJ, et al. · · 2019 · cited 185 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
ImportanceExposure to a weightless environment during spaceflight results in a chronic headward blood and tissue fluid shift compared with the upright posture on Earth, with unknown consequences to cerebral venous outflow.
Closing excerpt
Lower body negative pressure may be a promising countermeasure to enhance venous blood flow in the upper body during spaceflight.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (267 words)

ImportanceExposure to a weightless environment during spaceflight results in a chronic headward blood and tissue fluid shift compared with the upright posture on Earth, with unknown consequences to cerebral venous outflow.ObjectivesTo assess internal jugular vein (IJV) flow and morphology during spaceflight and to investigate if lower body negative pressure is associated with reversing the headward fluid shift experienced during spaceflight.Design, setting, and participantsThis prospective cohort study included 11 International Space Station crew members participating in long-duration spaceflight missions . Internal jugular vein measurements from before launch and approximately 40 days after landing were acquired in 3 positions: seated, supine, and 15° head-down tilt. In-flight IJV measurements were acquired at approximately 50 days and 150 days into spaceflight during normal spaceflight conditions as well as during use of lower body negative pressure. Data were analyzed in June 2019.ExposuresPosture changes on Earth, spaceflight, and lower body negative pressure.Main outcomes and measuresUltrasonographic assessments of IJV cross-sectional area, pressure, blood flow, and thrombus formation.ResultsThe 11 healthy crew members included in the study (mean [SD] age, 46.9 [6.3] years, 9 [82%] men) spent a mean (SD) of 210 (76) days in space. Mean IJV area increased from 9.8 (95% CI, -1.2 to 20.7) mm2 in the preflight seated position to 70.3 (95% CI, 59.3-81.2) mm2 during spaceflight (P Conclusions and relevanceThis cohort study found stagnant and retrograde blood flow associated with spaceflight in the IJVs of astronauts and IJV thrombosis in at least 1 astronaut, a newly discovered risk associated with spaceflight. Lower body negative pressure may be a promising countermeasure to enhance venous blood flow in the upper body during spaceflight.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 31722025 · DOI · PMC6902784

TWIST1 Integrates Endothelial Responses to Flow in Vascular Dysfunction and Atherosclerosis [2]

Research article Mahmoud MM, Kim HR, Xing R, Hsiao S, Mammoto A, Chen J, et al. · · 2016 · cited 132 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
RationaleBlood flow-induced shear stress controls endothelial cell (EC) physiology during atherosclerosis via transcriptional mechanisms that are incompletely understood.
Closing excerpt
Thus, pleiotropic functions of TWIST control vascular disease and development.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (230 words)

RationaleBlood flow-induced shear stress controls endothelial cell (EC) physiology during atherosclerosis via transcriptional mechanisms that are incompletely understood. The mechanosensitive transcription factor TWIST is expressed during embryogenesis, but its role in EC responses to shear stress and focal atherosclerosis is unknown.ObjectiveTo investigate whether TWIST regulates endothelial responses to shear stress during vascular dysfunction and atherosclerosis and compare TWIST function in vascular development and disease.Methods and resultsThe expression and function of TWIST1 was studied in EC in both developing vasculature and during the initiation of atherosclerosis. In zebrafish, twist was expressed in early embryonic vasculature where it promoted angiogenesis by inducing EC proliferation and migration. In adult porcine and murine arteries, TWIST1 was expressed preferentially at low shear stress regions as evidenced by quantitative polymerase chain reaction and en face staining. Moreover, studies of experimental murine carotid arteries and cultured EC revealed that TWIST1 was induced by low shear stress via a GATA4-dependent transcriptional mechanism. Gene silencing in cultured EC and EC-specific genetic deletion in mice demonstrated that TWIST1 promoted atherosclerosis by inducing inflammation and enhancing EC proliferation associated with vascular leakiness.ConclusionsTWIST expression promotes developmental angiogenesis by inducing EC proliferation and migration. In addition to its role in development, TWIST is expressed preferentially at low shear stress regions of adult arteries where it promotes atherosclerosis by inducing EC proliferation and inflammation. Thus, pleiotropic functions of TWIST control vascular disease and development.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 27245171 · DOI · PMC4959828

Regulation of blood flow and volume exchange across the microcirculation [3]

Review article Jacob M, Chappell D, Becker BF · · 2016 · cited 103 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
Oxygen delivery to cells is the basic prerequisite of life.
Closing excerpt
We are just beginning to appreciate that a major factor for maintaining tissue fluid homeostasis appears to be the integrity of the endothelial glycocalyx.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (351 words)

Oxygen delivery to cells is the basic prerequisite of life. Within the human body, an ingenious oxygen delivery system, comprising steps of convection and diffusion from the upper airways via the lungs and the cardiovascular system to the microvascular area, bridges the gap between oxygen in the outside airspace and the interstitial space around the cells. However, the complexity of this evolutionary development makes us prone to pathophysiological problems. While those problems related to respiration and macrohemodynamics have already been successfully addressed by modern medicine, the pathophysiology of the microcirculation is still often a closed book in daily practice. Nevertheless, here as well, profound physiological understanding is the only key to rational therapeutic decisions. The prime guarantor of tissue oxygenation is tissue blood flow. Therefore, on the premise of intact macrohemodynamics, the microcirculation has three major responsibilities: 1) providing access for oxygenated blood to the tissues and appropriate return of volume; 2) maintaining global tissue flood flow, even in the face of changes in central blood pressure; and 3) linking local blood flow to local metabolic needs. It is an intriguing concept of nature to do this mainly by local regulatory mechanisms, impacting primarily on flow resistance, be this via endothelial or direct smooth muscle actions. The final goal of microvascular blood flow per unit of time is to ensure the needed exchange of substances between tissue and blood compartments. The two principle means of accomplishing this are diffusion and filtration. While simple diffusion is the quantitatively most important form of capillary exchange activity for the respiratory gases, water flux across the blood-brain barrier is facilitated via preformed specialized channels, the aquaporines. Beyond that, the vascular barrier is practically nowhere completely tight for water, with paracellular filtration giving rise to generally low but permanent fluid flux outwards into the interstitial space at the microvascular high pressure segment. At the more leaky venular aspect, both filtration and diffusion allow for bidirectional passage of water, nutrients, and waste products. We are just beginning to appreciate that a major factor for maintaining tissue fluid homeostasis appears to be the integrity of the endothelial glycocalyx.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 27765054 · DOI · PMC5073467

Comparative Assessment of Retinal Blood Flow Velocity Changes Following Brimonidine and Brinzolamide Administration Using Retinal Function Imaging [4]

Randomized controlled trial Enz TJ, Bittner M, Tribble JR, Williams PA, Thiel MA, Schmid MK, et al. · · 2022 · cited 4 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
PurposeImpaired ocular blood flow has been associated with the etiopathogenesis of glaucoma.
Closing excerpt
The findings indicate that beside the lowering of IOP there is no evidence for an additional effect on the development of glaucoma.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (328 words)

PurposeImpaired ocular blood flow has been associated with the etiopathogenesis of glaucoma. Topical brimonidine lowers intraocular pressure, a major glaucoma risk factor. However, brimonidine's influence on retinal blood flow remains to be fully elucidated. Our aim was to compare the effect of topical brimonidine and brinzolamide administration on retinal blood flow velocity in second and third order vessels in healthy adults using the retinal function imager.MethodsIn 10 healthy probands between 23 and 32 years of age, one eye was randomly selected to receive 2 treatment rounds with 3 single doses of brimonidine 2 mg/mL and brinzolamide 10 mg/mL at 12-hour intervals each. The fellow eyes served as intra-individual controls. Immediately before the first drop and 2 hours after the last drop of each treatment round, all subjects were examined, including Goldmann tonometry, Pascal tonometry, assessment of retinal blood flow velocity using the retinal function imager, as well as blood pressure and pulse measurements.ResultsIntraocular pressure decreased significantly in treated eyes while remaining stable in control eyes, indicating reliable application of brimonidine and brinzolamide drops. In contrast, retinal blood flow velocities did not demonstrate any significant differences between groups after both treatment rounds.ConclusionsNeither brimonidine nor brinzolamide appear to alter retinal blood flow velocity in a clinically relevant manner. The slight velocity changes detected in our study are likely physiologic fluctuations. Our findings do not support the rationale of a detrimental effect of topical brimonidine on ocular blood flow and hence brimonidine may be further administered for lowering intraocular pressure with the appropriate caution. However, our study is strongly limited by the small sample size and, thus, further research with larger cohorts of healthy volunteers and patients with glaucoma is needed to confirm the results.Translational relevanceThe study provides information about the effect of the topically administered antiglaucoma medications brimonidine and brinzolamide on the ocular blood flow and its regulation. The findings indicate that beside the lowering of IOP there is no evidence for an additional effect on the development of glaucoma.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 35103799 · DOI · PMC8819484

Key reviews and meta-analyses

The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.

  • Research article Expert consensus and evidence-based recommendations for the assessment of flow-mediated dilation in humans [5]
    Thijssen DHJ, Bruno RM, van Mil ACCM, Holder SM, Faita F, Greyling A, et al. · Eur Heart J · 2019 · cited 759 times (Europe PMC)
  • Research article Flow-mediated dilation and cardiovascular risk prediction: a systematic review with meta-analysis [6]
    Ras RT, Streppel MT, Draijer R, Zock PL · Int J Cardiol · 2013 · cited 482 times (Europe PMC)
  • Research article Flow-mediated dilation and cardiovascular event prediction: does nitric oxide matter? [7]
    Green DJ, Jones H, Thijssen D, Cable NT, Atkinson G · Hypertension · 2011 · cited 420 times (Europe PMC)
  • Research article Patient-specific modeling of blood flow and pressure in human coronary arteries [8]
    Kim HJ, Vignon-Clementel IE, Coogan JS, Figueroa CA, Jansen KE, Taylor CA · Ann Biomed Eng · 2010 · cited 389 times (Europe PMC)
  • Research article Risk of mortality and cardiovascular disease associated with the ankle-brachial index: Systematic review [9]
    Heald CL, Fowkes FG, Murray GD, Price JF, Ankle Brachial Index Collaboration · Atherosclerosis · 2006 · cited 315 times (Europe PMC)
  • Research article Synthetic aperture ultrasound imaging [10]
    Jensen JA, Nikolov SI, Gammelmark KL, Pedersen MH · Ultrasonics · 2006 · cited 311 times (Europe PMC)

References

  1. Marshall-Goebel K, Laurie SS, Alferova IV, Arbeille P, Auñón-Chancellor SM, Ebert DJ, et al.. Assessment of Jugular Venous Blood Flow Stasis and Thrombosis During Spaceflight. . 2019. PMID 31722025 · DOI · PMC6902784
  2. Mahmoud MM, Kim HR, Xing R, Hsiao S, Mammoto A, Chen J, et al.. TWIST1 Integrates Endothelial Responses to Flow in Vascular Dysfunction and Atherosclerosis. . 2016. PMID 27245171 · DOI · PMC4959828
  3. Jacob M, Chappell D, Becker BF. Regulation of blood flow and volume exchange across the microcirculation. . 2016. PMID 27765054 · DOI · PMC5073467
  4. Enz TJ, Bittner M, Tribble JR, Williams PA, Thiel MA, Schmid MK, et al.. Comparative Assessment of Retinal Blood Flow Velocity Changes Following Brimonidine and Brinzolamide Administration Using Retinal Function Imaging. . 2022. PMID 35103799 · DOI · PMC8819484
  5. Thijssen DHJ, Bruno RM, van Mil ACCM, Holder SM, Faita F, Greyling A, et al.. Expert consensus and evidence-based recommendations for the assessment of flow-mediated dilation in humans. Eur Heart J. 2019. PMID 31211361 · DOI
  6. Ras RT, Streppel MT, Draijer R, Zock PL. Flow-mediated dilation and cardiovascular risk prediction: a systematic review with meta-analysis. Int J Cardiol. 2013. PMID 23041097 · DOI
  7. Green DJ, Jones H, Thijssen D, Cable NT, Atkinson G. Flow-mediated dilation and cardiovascular event prediction: does nitric oxide matter?. Hypertension. 2011. PMID 21263128 · DOI
  8. Kim HJ, Vignon-Clementel IE, Coogan JS, Figueroa CA, Jansen KE, Taylor CA. Patient-specific modeling of blood flow and pressure in human coronary arteries. Ann Biomed Eng. 2010. PMID 20559732 · DOI
  9. Heald CL, Fowkes FG, Murray GD, Price JF, Ankle Brachial Index Collaboration. Risk of mortality and cardiovascular disease associated with the ankle-brachial index: Systematic review. Atherosclerosis. 2006. PMID 16620828 · DOI
  10. Jensen JA, Nikolov SI, Gammelmark KL, Pedersen MH. Synthetic aperture ultrasound imaging. Ultrasonics. 2006. PMID 16959281 · DOI

About this article

Sources
NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
Verification
Every reference was resolved against PubMed on 2026-10-31; title, year and DOI matched.
Review state
automated source verified; no human expert review has been recorded yet.
Version
1, last updated 2026-10-29.

See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.

Evidence strength

EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.

Included with the Researcher plan

Reading every article stays free. This computed view is part of the paid plans.

See plans Sign in

Your notes

Notes and highlights stay in this browser only; they are not sent to EvidenceHelix.

Related research topics

  • Cardiac OutputCardiovascular Medicine
  • Stroke VolumeCardiovascular Medicine
  • Pulsatile FlowCardiovascular Medicine
  • Blood VolumeCardiovascular Medicine
  • Cerebral Blood VolumeCardiovascular Medicine
  • Blood ViscosityCardiovascular Medicine

All 105 articles in Cardiovascular Medicine →

At a glance

62,016
PubMed records on this heading
7%
published since 2020
3,201
review articles
1,907
randomized trials
10
verified references below

Counts come from PubMed on 2026-10-29; they show how much has been written, not how strong the evidence is.

Related topics See all →

  • Cardiac OutputCardiovascular Medicine
  • Stroke VolumeCardiovascular Medicine
  • Pulsatile FlowCardiovascular Medicine
  • Blood VolumeCardiovascular Medicine
  • Cerebral Blood VolumeCardiovascular Medicine

My notes & annotations (0)

Nothing yet. Select text and press Highlight, or write a note in the Notes tab. Stored in this browser only.

Sources

  • NLM MeSH record ↗
  • PubMed search used ↗

EvidenceLib is a research-education resource, not medical advice. It does not diagnose, prescribe or recommend starting, stopping or changing any treatment. Talk to a qualified clinician about your own situation. Methods, sources and licences · Legal · Support