Definition and research guide
This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.
Content available: 4 complete abstracts (791 words), 7 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.
Definition
Global longitudinal strain (GLS) is a measure of ventricular function derived from 2-dimensional echocardiographic images by quantifying the relative length change in myocardial length between end-diastole and end-systole. GLS is used to predict cardiovascular outcomes and has been proposed to be a better measure of cardiac dysfunction than ventricular ejection fraction.
Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.
Also known as: Global Longitudinal Strains; Longitudinal Strain, Global; Longitudinal Strains, Global; Strain, Global Longitudinal; Strains, Global Longitudinal; Left Ventricular Global Longitudinal Strain; LV-GLS; LV GLS.
Where it fits in the MeSH classification
- Broader topics
- Hemodynamics
Related concepts
Research landscape
PubMed indexes 626 records tagged with the MeSH heading “Global Longitudinal Strain” (counts retrieved 2026-10-29). 626 of them (100.0%) were published from 2020 onward, and the busiest period so far is 2020 onward with 626 records.
Reviews account for 64 records (10.2%) and meta-analyses for 34. Randomized controlled trials number 15 (2.4%) as a share of all records on the topic.
Show the data
| Period | Records |
|---|---|
| through 1999 | 0 |
| 2000-2009 | 0 |
| 2010-2019 | 0 |
| 2020 onward | 626 |
Publication-type chart data
| Type | Records | Share |
|---|---|---|
| Reviews | 64 | 10.2% |
| Meta-analyses | 34 | 5.4% |
| Randomized controlled trials | 15 | 2.4% |
Method: PubMed query "Global Longitudinal Strain"[MeSH Terms] with publication-type and date filters, retrieved 2026-10-29.
Reading the evidence in cardiovascular medicine
Cardiovascular medicine has an unusually large body of randomized trials, so the type of outcome matters: hard clinical events such as death, heart attack and stroke carry more weight than changes in blood pressure, cholesterol or imaging markers that only predict risk. Observational studies can show associations but are confounded by age, lifestyle and other illness. Check whether a result is about prevention or treatment, the baseline risk of participants, and the absolute rather than only the relative size of any benefit.
Evidence from open-access studies
These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.
The impact of angles of insonation on left and right ventricular global longitudinal strain estimation in fetal speckle tracking echocardiography [1]
Abstract reading summary — source excerpts
- Opening excerpt
- ObjectivesTwo-dimensional speckle tracking echocardiography has been considered an angle-independent modality.
- Closing excerpt
- ConclusionsThere is no evidence of a difference in fetal left and right ventricular global longitudinal strain between the different angles of insonation in fetal two-dimensional speckle tracking echocardiography.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (228 words)
ObjectivesTwo-dimensional speckle tracking echocardiography has been considered an angle-independent modality. However, current literature is limited and inconclusive on the actual impact of angle of insonation on strain values. Therefore, the primary objective of this study was to assess the impact of angles of insonation on the estimation of fetal left ventricular and right ventricular global longitudinal strain. Secondarily, the impact of different definitions for angles of insonation was investigated in a sensitivity analysis.MethodsThis is a retrospective analysis of a prospective longitudinal cohort study with 124 healthy subjects. The analyses were based on the four-chamber view ultrasound clips taken between 18+0 and 21+6 weeks of gestation. Angles of insonation were categorized into three groups: up/down, oblique and perpendicular. The mean fetal left and right ventricular and global longitudinal strain values corresponding to these three groups were compared by an ANOVA test corrected for heteroscedasticity.ResultsFetal left and right ventricular global longitudinal strain values were not statistically different between the three angles of insonation (p-value >0.062 and >0.149, respectively). When applying another definition for angles of insonation in the sensitivity analysis, the mean left ventricular global longitudinal strain value was significantly decreased for the oblique compared to the up/down angle of insonation (p-value 0.041).ConclusionsThere is no evidence of a difference in fetal left and right ventricular global longitudinal strain between the different angles of insonation in fetal two-dimensional speckle tracking echocardiography.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 37437044 · DOI · PMC10337891
The predictive value of left ventricular global longitudinal strain in normotensive critically ill septic patients [2]
Abstract reading summary — source excerpts
- Opening excerpt
- ObjectiveEvaluation of left ventricular systolic function using speckle tracking echocardiography is more sensitive than conventional echocardiographic measurement in detecting subtle left ventricular dysfunction in septic patients.
- Closing excerpt
- 7%; p ConclusionImpaired left ventricular global longitudinal strain is associated with mortality and provided predictive data in normotensive septic intensive care patients.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (167 words)
ObjectiveEvaluation of left ventricular systolic function using speckle tracking echocardiography is more sensitive than conventional echocardiographic measurement in detecting subtle left ventricular dysfunction in septic patients. Our purpose was to investigate the predictive significance of left ventricular global longitudinal strain in normotensive septic intensive care patients.MethodsThis observational, prospective cohort study included septic normotensive adults admitted to the intensive care unit between June 1, 2021, and August 31, 2021. Left ventricular systolic function was measured using speckle-tracking echocardiography within 24 hours of admission.ResultsOne hundred fifty-two patients were enrolled. The intensive care unit mortality rate was 27%. Left ventricular global longitudinal strain was less negative, which indicated worse left ventricular function in non-survivors than survivors (median [interquartile range], -15.2 [-17.2 - -12.5] versus -17.3 [-18.8 - -15.5]; p -17% (less negative than -17%, which indicated worse left ventricular function) showed a significantly higher mortality rate (39.2% versus 13.7%; p ConclusionImpaired left ventricular global longitudinal strain is associated with mortality and provided predictive data in normotensive septic intensive care patients.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 37712808 · DOI · PMC10406401
Decoupling Transmission and Transduction for Improved Durability of Highly Stretchable, Soft Strain Sensing: Applications in Human Health Monitoring [3]
Abstract reading summary — source excerpts
- Opening excerpt
- This work presents a modular approach to the development of strain sensors for large deformations.
- Closing excerpt
- The effects of friction and boundary conditions are also empirically assessed and discussed.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (192 words)
This work presents a modular approach to the development of strain sensors for large deformations. The proposed method separates the extension and signal transduction mechanisms using a soft, elastomeric transmission and a high-sensitivity microelectromechanical system (MEMS) transducer. By separating the transmission and transduction, they can be optimized independently for application-specific mechanical and electrical performance. This work investigates the potential of this approach for human health monitoring as an implantable cardiac strain sensor for measuring global longitudinal strain (GLS). The durability of the sensor was evaluated by conducting cyclic loading tests over one million cycles, and the results showed negligible drift. To account for hysteresis and frequency-dependent effects, a lumped-parameter model was developed to represent the viscoelastic behavior of the sensor. Multiple model orders were considered and compared using validation and test data sets that mimic physiologically relevant dynamics. Results support the choice of a second-order model, which reduces error by 73% compared to a linear calibration. In addition, we evaluated the suitability of this sensor for the proposed application by demonstrating its ability to operate on compliant, curved surfaces. The effects of friction and boundary conditions are also empirically assessed and discussed.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 36850551 · DOI · PMC9967534
Basal inferoseptal longitudinal strain deformation may indicate early cardiac involvement in wild-type carpal ATTR [4]
Abstract reading summary — source excerpts
- Opening excerpt
- Background and aimsWild-type transthyretin cardiac amyloidosis (ATTRwt-CA) is now increasingly identified as a cause of heart failure in older adults.
- Closing excerpt
- ConclusionsBasal inferoseptal LS impairment may indicate early cardiac involvement in individuals with carpal tunnel syndrome carrying ATTRwt deposits.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (204 words)
Background and aimsWild-type transthyretin cardiac amyloidosis (ATTRwt-CA) is now increasingly identified as a cause of heart failure in older adults. This study aimed to clarify the morphological and functional alterations of the left ventricle (LV) that define the early stage of this condition.MethodsWe prospectively evaluated 81 patients diagnosed with wild-type ATTR (ATTRwt) amyloidosis (mean age 77 ± 6 years; 88% male), categorized into three groups based on myocardial uptake on radioactive pyrophosphate scintigraphy and histological confirmation: (i) carpal ATTR without cardiac involvement (Group 1, n = 13), (ii) asymptomatic cardiac involvement (Group 2, n = 10) and (iii) overt heart failure (Group 3, n = 58).ResultsCompared with Group 3, Group 1 showed higher absolute global longitudinal strain (GLS) (median 19.0 [13.2-23.8]%, P 0.014 ng/mL) than in those with lower values (13.9 ± 5.6% vs. 7.4 ± 1.8%, P = .046) in Group 1. A basal inferoseptal LS cutoff of 9.1% identified high troponin-T with an area under the curve (AUC) of 0.833 (P = .005), outperforming GLS (AUC 0.306, P = .217), BNP (AUC 0.667, P = .292), and LV ejection fraction (AUC 0.556, P = .743).ConclusionsBasal inferoseptal LS impairment may indicate early cardiac involvement in individuals with carpal tunnel syndrome carrying ATTRwt deposits.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 41711216 · DOI · PMC13036830
Key reviews and meta-analyses
The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.
- Research article Left Ventricular Global Longitudinal Strain as a Marker of Subclinical Myocardial Dysfunction in Youths With Type 1 Diabetes Mellitus: An Updated Systematic Review and Meta-Analysis [5]
- Research article The role of global longitudinal strain in predicting fatal arrhythmic events in hypertrophic cardiomyopathy: An up-to-date systematic review and Meta-analysis [6]
- Research article Correlation across modalities and clinical phenotypes between left Ventricular global longitudinal strain by echocardiography and cardiac magnetic resonance [7]
References
- Nichting TJ, de Vet CM, van der Ven M, van der Woude DAA, Regis M, van Sloun RJG, et al.. The impact of angles of insonation on left and right ventricular global longitudinal strain estimation in fetal speckle tracking echocardiography. . 2023. PMID 37437044 · DOI · PMC10337891
- Omar T, İnci K, Oflu Y, Dilek M, Çelik ZB, Kına S, et al.. The predictive value of left ventricular global longitudinal strain in normotensive critically ill septic patients. . 2023. PMID 37712808 · DOI · PMC10406401
- Kight A, Pirozzi I, Liang X, McElhinney DB, Han AK, Dual SA, et al.. Decoupling Transmission and Transduction for Improved Durability of Highly Stretchable, Soft Strain Sensing: Applications in Human Health Monitoring. . 2023. PMID 36850551 · DOI · PMC9967534
- Tsuruda T, Ota T, Terada T, Nakada H, Ogata M, Tanaka M, et al.. Basal inferoseptal longitudinal strain deformation may indicate early cardiac involvement in wild-type carpal ATTR. . 2026. PMID 41711216 · DOI · PMC13036830
- Stamati A, Sotiriou G, Emmanoulidou-Fotoulaki E, Printza N, Kavga M, Christoforidis A. Left Ventricular Global Longitudinal Strain as a Marker of Subclinical Myocardial Dysfunction in Youths With Type 1 Diabetes Mellitus: An Updated Systematic Review and Meta-Analysis. Diabetes Metab Res Rev. 2026. PMID 42640083 · DOI · PMC13505227
- Bazoukis G, Liu H, Copti R, Saplaouras A, Nguyen TNM, Lee S, et al.. The role of global longitudinal strain in predicting fatal arrhythmic events in hypertrophic cardiomyopathy: An up-to-date systematic review and Meta-analysis. J Cardiol. 2026. PMID 42086169 · DOI
- Pascalis L, Fazzini L, Pugliesi GM, Restivo L, Cadeddu Dessalvi C. Correlation across modalities and clinical phenotypes between left Ventricular global longitudinal strain by echocardiography and cardiac magnetic resonance. Curr Probl Cardiol. 2026. PMID 41802481 · DOI
About this article
- Sources
- NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
- Verification
- Every reference was resolved against PubMed on 2026-10-31; title, year and DOI matched.
- Review state
- automated source verified; no human expert review has been recorded yet.
- Version
- 1, last updated 2026-10-29.
See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.
Evidence strength
EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.