Skip to content
EvidenceHelixEvidenceLib · Scientific Encyclopedia
⌘ K

Scientific library

EvidenceLib encyclopediaAll articles A–Z2,835Open textbooks209Open-access articles1,406Cancer study catalog458How it is made

My workspace this browser

Saved pages0Notes & annotations0

Recently viewed

Explore by field

Cancer and Oncology182Genetics and Genomics170Neuroscience185Cardiovascular Medicine180Immunology142Pharmacology173Molecular Biology161Infectious Diseases150Rare and Inherited Diseases181Clinical Research173Anatomy and Physiology613Drugs and Chemicals621Psychiatry and Psychology185Public Health and Nutrition178Diagnostics and Medical Technology125Respiratory Medicine113Digestive System and Liver91Metabolism and Endocrine Disease177Bones, Joints, Muscles and Skin213Kidney, Urology and Women's Health173Eye, Ear, Nose and Throat55
Plans & pricingCompare EvidenceHelix workspace plans
Library›EvidenceLib›Diagnostics and Medical Technology›Myelography

Continue where you left off ()

Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

Research reading room

Myelography

Diagnostics and Medical Technology · NLM MeSH · updated 2026-11-04 · version 1

Citations verified against PubMedNot yet clinician-reviewed10 referencesApproximately 5 min read

X-ray visualization of the spinal cord following injection of contrast medium into the spinal arachnoid space.

Table of Contents

1. Definition2. Research landscape3. Reading the evidence4. Open-access studies5. Key reviews6. References7. About this article

Definition and research guide

This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.

Content available: 4 complete abstracts (992 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.

Definition

X-ray visualization of the spinal cord following injection of contrast medium into the spinal arachnoid space.

Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.

Also known as: Myelographies; Cisternography, Myelographic; Myelographic Cisternography; Cisternographies, Myelographic; Myelographic Cisternographies.

Where it fits in the MeSH classification

Broader topics
Neuroradiography
Narrower topics
Magnetic Resonance Myelography

Research landscape

PubMed indexes 8,625 records tagged with the MeSH heading “Myelography” (counts retrieved 2026-11-04). 292 of them (3.4%) were published from 2020 onward, and the busiest period so far is through 1999 with 7,342 records.

Reviews account for 499 records (5.8%) and meta-analyses for 4. Randomized controlled trials number 70 (0.8%) as a share of all records on the topic. Randomized trials make up only a small share of this literature, so much of what is known comes from laboratory, observational or descriptive work.

PubMed records by publication periodthrough 1999: 7,342 records; 2000-2009: 619 records; 2010-2019: 372 records; 2020 onward: 292 records7,342through 19996192000-20093722010-20192922020 onward
Records in PubMed indexed with this heading, by publication period. Real counts from NCBI E-utilities; the final period covers only part of the current year. Volume reflects how much has been published, not how strong the evidence is.
Show the data
PeriodRecords
through 19997,342
2000-2009619
2010-2019372
2020 onward292
Share of records by publication typeReviews: 5.8 percent; Meta-analyses: 0.0 percent; Randomized controlled trials: 0.8 percentReviews5.8% (499)Meta-analyses0.0% (4)Randomized controlled trials0.8% (70)
Share of all PubMed records on this heading that carry each publication type. Types overlap with other records, so the shares do not sum to 100%.
Publication-type chart data
Publication types among 8,625 PubMed records
TypeRecordsShare
Reviews4995.8%
Meta-analyses40.0%
Randomized controlled trials700.8%

Method: PubMed query "Myelography"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.

Reading the evidence in diagnostics and medical technology

A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.

Evidence from open-access studies

These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.

Study comparison — selected abstracts, not a systematic review
Study / authorsYearSource label / designEurope PMC citationsLicence / source
Diagnostic accuracy of diagnostic imaging for lumbar disc herniation in adults with low back pain or sciatica is unknown; a systematic review
Kim JH, van Rijn RM, van Tulder MW, Koes BW, de Boer MR, Ginai AZ, et al.
2018Systematic review
Design not recorded in structured metadata
54cc by
PMID 30151119 · DOI · PMC6102824
Role of Conventional Dynamic Myelography for Detection of High-Flow Cerebrospinal Fluid Leaks : Optimizing the Technique
Piechowiak EI, Pospieszny K, Haeni L, Jesse CM, Peschi G, Mosimann PJ, et al.
2021Research article
Design not recorded in structured metadata
36cc by
PMID 32845353 · DOI · PMC8463391
The role of CT myelography in sparing the spinal cord during definitive radiotherapy in vertebral hemangioma
Sudha SP, Gopalakrishnan MS, Saravanan K
2017Research article
Design not recorded in structured metadata
8cc by
PMID 28834112 · DOI · PMC5874956
Spontaneous intracranial hypotension due to CSF-venous fistula: Evaluation of renal accumulation of contrast following decubitus myelography and maintained decubitus CT to improve fistula localization
Farb RI, O'Reilly ST, Hendriks EJ, Peng PW, Massicotte EM, Hoydonckx Y, et al.
2025Research article
Design not recorded in structured metadata
6cc by
PMID 37211661 · DOI · PMC12280252

Diagnostic accuracy of diagnostic imaging for lumbar disc herniation in adults with low back pain or sciatica is unknown; a systematic review [1]

Systematic review Kim JH, van Rijn RM, van Tulder MW, Koes BW, de Boer MR, Ginai AZ, et al. · · 2018 · cited 54 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
Main textWe aim to summarize the available evidence on the diagnostic accuracy of imaging (index test) compared to surgery (reference test) for identifying lumbar disc herniation (LDH) in adult patients.
Closing excerpt
Concerning the older techniques we found moderate diagnostic accuracy for all CT, myelography and MRI, indicating a large proportion of false positives and negatives.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (222 words)

Main textWe aim to summarize the available evidence on the diagnostic accuracy of imaging (index test) compared to surgery (reference test) for identifying lumbar disc herniation (LDH) in adult patients.For this systematic review we searched MEDLINE, EMBASE and CINAHL (June 2017) for studies that assessed the diagnostic accuracy of imaging for LDH in adult patients with low back pain and surgery as the reference standard. Two review authors independently selected studies, extracted data and assessed risk of bias. We calculated summary estimates of sensitivity and specificity using bivariate analysis, generated linked ROC plots in case of direct comparison of diagnostic imaging tests and assessed the quality of evidence using the GRADE-approach.We found 14 studies, all but one done before 1995, including 940 patients. Nine studies investigated Computed Tomography (CT), eight myelography and six Magnetic Resonance Imaging (MRI). The prior probability of LDH varied from 48.6 to 98.7%. The summary estimates for MRI and myelography were comparable with CT (sensitivity: 81.3% (95%CI 72.3-87.7%) and specificity: 77.1% (95%CI 61.9-87.5%)). The quality of evidence was moderate to very low.ConclusionsThe diagnostic accuracy of CT, myelography and MRI of today is unknown, as we found no studies evaluating today's more advanced imaging techniques. Concerning the older techniques we found moderate diagnostic accuracy for all CT, myelography and MRI, indicating a large proportion of false positives and negatives.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 30151119 · DOI · PMC6102824

Role of Conventional Dynamic Myelography for Detection of High-Flow Cerebrospinal Fluid Leaks : Optimizing the Technique [2]

Research article Piechowiak EI, Pospieszny K, Haeni L, Jesse CM, Peschi G, Mosimann PJ, et al. · · 2021 · cited 36 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
BackgroundSpinal imaging is essential to identify and localize cerebrospinal fluid (CSF) leaks in spontaneous intracranial hypotension (SIH) patients when targeted treatment is necessary.
Closing excerpt
For CSF venous fistulas, however, other dynamic examinations, such as digital subtraction myelography, seem more appropriate.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (248 words)

BackgroundSpinal imaging is essential to identify and localize cerebrospinal fluid (CSF) leaks in spontaneous intracranial hypotension (SIH) patients when targeted treatment is necessary.PurposeProvide an in-depth presentation of the conventional dynamic myelography (CDM) technique for localizing spinal CSF leaks in SIH patients.Material and methodsConsecutive SIH patients with a CSF leak confirmed on CDM and postmyelography computed tomography (CT) investigated at our institution between 2013 and 2019 were retrospectively analyzed. Intraoperative reports were reviewed to confirm the accuracy of CDM.ResultsIn total, 62 patients (mean age 45 years) were included; 48 with a ventral dural tear, 12 with a meningeal diverticulum, and in 2 patients positive for spinal longitudinal extradural CSF collection the site remained unclear. The leak was identified during the first and the second CDM in 43 and 17 patients, respectively. The use of CDM correctly identified the site of the CSF leak in all but one patient undergoing surgical closure (45/46, 98%). The mean fluoroscopy time was 7.8 min (range 1.8-14.4 min) with a radiation dose for a single examination of 310 mGy (range 28-1237 mGy).ConclusionThe CDM procedure has a high accuracy for spinal CSF leak localization including dural tears and spinal nerve diverticula. It is the technique with the highest temporal resolution, is robust to breathing artifacts, allows great flexibility regarding patient positioning, compares favorably to other dynamic examinations with respect to the radiation dose and does not require general anesthesia. For CSF venous fistulas, however, other dynamic examinations, such as digital subtraction myelography, seem more appropriate.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 32845353 · DOI · PMC8463391

The role of CT myelography in sparing the spinal cord during definitive radiotherapy in vertebral hemangioma [3]

Research article Sudha SP, Gopalakrishnan MS, Saravanan K · · 2017 · cited 8 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
IntroductionThe spinal cord is poorly visualized on CT images but is well visualized in MRI images.
Closing excerpt
ConclusionCT myelogram in conjunction with CT simulation is particularly useful in cases where the tumor margin is very close to the cord and spinal implants are causing distortion of magnetic resonance images.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (286 words)

IntroductionThe spinal cord is poorly visualized on CT images but is well visualized in MRI images. However, implants used for spinal stabilization can produce artifacts on the MRI images which can interfere with identification of the cord. CT myelography in conjunction with CT simulation helps to clearly delineate the cord.Materials and methodsCT simulation was done in a patient with vertebral hemangioma. Pre- and post myelography images were obtained. Two plans were generated on pre and post myelography CT images using Eclipse™ treatment planning system (TPS) version 10.0, Varian Medical Systems, USA. The prescribed total dose to PTV was 40 Gy in 20 fractions.ResultsThe cord was poorly visualized in the premyelogram CT images. The titanium implants used for spinal cord stabilization produced artifacts in the MRI images. Figure Post myelogram, the contrast lit up the spinal cord. There was an overlap of 0.75 cc volume of the spinal cord with the PTV in the premyelogram images. This volume was reduced to 0 cc in the post myelogram images. There was an overlap of 5.4 cc volume of the PRV of spinal cord with the PTV in the premyelogram images which was reduced to 1 cc in the post myelogram images. The overlap region between the PTV and spinal cord received around 71% of the prescribed dose in premyelogram CT could be reduced to 0% in the post myelogram CT. The mean dose received by the overlap PRV spinal cord and PTV could be increased from 70% in the premyelogram to 92% in the post myelogram plans.ConclusionCT myelogram in conjunction with CT simulation is particularly useful in cases where the tumor margin is very close to the cord and spinal implants are causing distortion of magnetic resonance images.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 28834112 · DOI · PMC5874956

Spontaneous intracranial hypotension due to CSF-venous fistula: Evaluation of renal accumulation of contrast following decubitus myelography and maintained decubitus CT to improve fistula localization [4]

Research article Farb RI, O'Reilly ST, Hendriks EJ, Peng PW, Massicotte EM, Hoydonckx Y, et al. · · 2025 · cited 6 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
PurposePresented here is a strategy of sequential lateral decubitus digital subtraction myelography (LDDSM) followed closely by lateral decubitus CT (LDCT) to facilitate cerebrospinal fluid (CSF)-venous fistula (CVF) localization.
Closing excerpt
ConclusionThe strategy of sequential LDDSM-LDCT coupled with evaluation of renal accumulation of contrast agent appears to improve the rate of CVF localization and warrants further evaluation.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (236 words)

PurposePresented here is a strategy of sequential lateral decubitus digital subtraction myelography (LDDSM) followed closely by lateral decubitus CT (LDCT) to facilitate cerebrospinal fluid (CSF)-venous fistula (CVF) localization.Materials and MethodsThis is a retrospective analysis of patients referred to our institution for evaluation of CSF leak. Patients with Type 1 and Type 2 leaks, and those not displaying MR brain stigmata of intracranial hypotension were excluded. All patients underwent consecutive LDDSM and LDCT. If the CVF was not localized on the first LDDSM-LDCT pair the patient returned for contralateral examinations. Images were reviewed for CVF and for accumulation of contrast within the renal pelvises expressed as a renal pelvis contrast score (RPCS) in Hounsfield units (HU).ResultsTwenty-two patients were included in this study. In 21 of 22 patients (95%) a CVF was identified yielding an RPCS for the LDDSM-LDCT pair ipsilateral to the CVF ranging from 71 to 423 with an average of 146 HU. An RPCS of the negative side LDDSM-LDCT pair contralateral to a CVF was available in 8 patients and averaged 51 HU. In 4 patients the initial bilateral LDDSM-LDCT pairs did not reveal the location of the CVF however in 3 of these 4 cases the CVF was revealed on a third LDDSM repeated ipsilateral to the higher RPCS.ConclusionThe strategy of sequential LDDSM-LDCT coupled with evaluation of renal accumulation of contrast agent appears to improve the rate of CVF localization and warrants further evaluation.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 37211661 · DOI · PMC12280252

Key reviews and meta-analyses

The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.

  • Research article Diagnosis of lumbar spinal stenosis in adults: a metaanalysis of the accuracy of CT, MR, and myelography [5]
    Kent DL, Haynor DR, Larson EB, Deyo RA · AJR Am J Roentgenol · 1992 · cited 124 times (Europe PMC)
  • Research article Imaging of skull base cerebrospinal fluid leaks in adults [6]
    Lloyd KM, DelGaudio JM, Hudgins PA · Radiology · 2008 · cited 119 times (Europe PMC)
  • Research article Myelographic Techniques for the Detection of Spinal CSF Leaks in Spontaneous Intracranial Hypotension [7]
    Kranz PG, Luetmer PH, Diehn FE, Amrhein TJ, Tanpitukpongse TP, Gray L · AJR Am J Roentgenol · 2016 · cited 107 times (Europe PMC)
  • Research article CSF-Venous Fistulas: Anatomy and Diagnostic Imaging [8]
    Kranz PG, Gray L, Malinzak MD, Houk JL, Kim DK, Amrhein TJ · AJR Am J Roentgenol · 2021 · cited 75 times (Europe PMC)
  • Research article Lateral Decubitus Digital Subtraction Myelography: Tips, Tricks, and Pitfalls [9]
    Kim DK, Brinjikji W, Morris PP, Diehn FE, Lehman VT, Liebo GB, et al. · AJNR Am J Neuroradiol · 2020 · cited 73 times (Europe PMC)
  • Research article Spontaneous Intracranial Hypotension: Imaging in Diagnosis and Treatment [10]
    Amrhein TJ, Kranz PG · Radiol Clin North Am · 2019 · cited 43 times (Europe PMC)

References

  1. Kim JH, van Rijn RM, van Tulder MW, Koes BW, de Boer MR, Ginai AZ, et al.. Diagnostic accuracy of diagnostic imaging for lumbar disc herniation in adults with low back pain or sciatica is unknown; a systematic review. . 2018. PMID 30151119 · DOI · PMC6102824
  2. Piechowiak EI, Pospieszny K, Haeni L, Jesse CM, Peschi G, Mosimann PJ, et al.. Role of Conventional Dynamic Myelography for Detection of High-Flow Cerebrospinal Fluid Leaks : Optimizing the Technique. . 2021. PMID 32845353 · DOI · PMC8463391
  3. Sudha SP, Gopalakrishnan MS, Saravanan K. The role of CT myelography in sparing the spinal cord during definitive radiotherapy in vertebral hemangioma. . 2017. PMID 28834112 · DOI · PMC5874956
  4. Farb RI, O'Reilly ST, Hendriks EJ, Peng PW, Massicotte EM, Hoydonckx Y, et al.. Spontaneous intracranial hypotension due to CSF-venous fistula: Evaluation of renal accumulation of contrast following decubitus myelography and maintained decubitus CT to improve fistula localization. . 2025. PMID 37211661 · DOI · PMC12280252
  5. Kent DL, Haynor DR, Larson EB, Deyo RA. Diagnosis of lumbar spinal stenosis in adults: a metaanalysis of the accuracy of CT, MR, and myelography. AJR Am J Roentgenol. 1992. PMID 1533084 · DOI
  6. Lloyd KM, DelGaudio JM, Hudgins PA. Imaging of skull base cerebrospinal fluid leaks in adults. Radiology. 2008. PMID 18710972 · DOI
  7. Kranz PG, Luetmer PH, Diehn FE, Amrhein TJ, Tanpitukpongse TP, Gray L. Myelographic Techniques for the Detection of Spinal CSF Leaks in Spontaneous Intracranial Hypotension. AJR Am J Roentgenol. 2016. PMID 26700332 · DOI
  8. Kranz PG, Gray L, Malinzak MD, Houk JL, Kim DK, Amrhein TJ. CSF-Venous Fistulas: Anatomy and Diagnostic Imaging. AJR Am J Roentgenol. 2021. PMID 34191547 · DOI
  9. Kim DK, Brinjikji W, Morris PP, Diehn FE, Lehman VT, Liebo GB, et al.. Lateral Decubitus Digital Subtraction Myelography: Tips, Tricks, and Pitfalls. AJNR Am J Neuroradiol. 2020. PMID 31857327 · DOI · PMC6975319
  10. Amrhein TJ, Kranz PG. Spontaneous Intracranial Hypotension: Imaging in Diagnosis and Treatment. Radiol Clin North Am. 2019. PMID 30709479 · DOI

About this article

Sources
NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
Verification
Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
Review state
automated source verified; no human expert review has been recorded yet.
Version
1, last updated 2026-11-04.

See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.

Evidence strength

EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.

Included with the Researcher plan

Reading every article stays free. This computed view is part of the paid plans.

See plans Sign in

Your notes

Notes and highlights stay in this browser only; they are not sent to EvidenceHelix.

Related research topics

  • Brain MappingDiagnostics and Medical Technology
  • ConnectomeDiagnostics and Medical Technology
  • Diffusion Tensor ImagingDiagnostics and Medical Technology
  • Functional NeuroimagingDiagnostics and Medical Technology
  • NeuroimagingDiagnostics and Medical Technology
  • AortographyDiagnostics and Medical Technology

All 110 articles in Diagnostics and Medical Technology →

At a glance

8,625
PubMed records on this heading
3%
published since 2020
499
review articles
70
randomized trials
10
verified references below

Counts come from PubMed on 2026-11-04; they show how much has been written, not how strong the evidence is.

Related topics See all →

  • Brain MappingDiagnostics and Medical Technology
  • ConnectomeDiagnostics and Medical Technology
  • Diffusion Tensor ImagingDiagnostics and Medical Technology
  • Functional NeuroimagingDiagnostics and Medical Technology
  • NeuroimagingDiagnostics and Medical Technology

My notes & annotations (0)

Nothing yet. Select text and press Highlight, or write a note in the Notes tab. Stored in this browser only.

Sources

  • NLM MeSH record ↗
  • PubMed search used ↗

EvidenceLib is a research-education resource, not medical advice. It does not diagnose, prescribe or recommend starting, stopping or changing any treatment. Talk to a qualified clinician about your own situation. Methods, sources and licences · Rights and removal requests · Legal · Support