Skip to content
EvidenceHelixEvidenceLib · Scientific Encyclopedia
⌘ K

Scientific library

EvidenceLib encyclopediaAll articles A–Z2,835Open textbooks209Open-access articles1,406Cancer study catalog458How it is made

My workspace this browser

Saved pages0Notes & annotations0

Recently viewed

Explore by field

Cancer and Oncology182Genetics and Genomics170Neuroscience185Cardiovascular Medicine180Immunology142Pharmacology173Molecular Biology161Infectious Diseases150Rare and Inherited Diseases181Clinical Research173Anatomy and Physiology613Drugs and Chemicals621Psychiatry and Psychology185Public Health and Nutrition178Diagnostics and Medical Technology125Respiratory Medicine113Digestive System and Liver91Metabolism and Endocrine Disease177Bones, Joints, Muscles and Skin213Kidney, Urology and Women's Health173Eye, Ear, Nose and Throat55
Plans & pricingCompare EvidenceHelix workspace plans
Library›EvidenceLib›Diagnostics and Medical Technology›Echo-Planar Imaging

Continue where you left off ()

Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

Research reading room

Echo-Planar Imaging

Diagnostics and Medical Technology · NLM MeSH · updated 2026-11-04 · version 1

Citations verified against PubMedNot yet clinician-reviewed10 referencesApproximately 5 min read

A type of magnetic resonance imaging that uses only one nuclear spin excitation per image and therefore can obtain images in a fraction of a second rather than the minutes required in traditional MRI techniques.

Table of Contents

1. Definition2. Research landscape3. Reading the evidence4. Open-access studies5. Key reviews6. References7. About this article

Definition and research guide

This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.

Content available: 4 complete abstracts (972 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.

Definition

A type of magnetic resonance imaging that uses only one nuclear spin excitation per image and therefore can obtain images in a fraction of a second rather than the minutes required in traditional MRI techniques. It is used in a variety of medical and scientific applications.

Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.

Also known as: Echo Planar Imaging; Echo-Planar Imagings; Imaging, Echo-Planar; Imagings, Echo-Planar; Echoplanar Imaging; Echoplanar Imagings; Imaging, Echoplanar; Imagings, Echoplanar.

Where it fits in the MeSH classification

Broader topics
Magnetic Resonance Imaging

Related concepts

  • Magnetic Resonance Imaging

Research landscape

PubMed indexes 5,257 records tagged with the MeSH heading “Echo-Planar Imaging” (counts retrieved 2026-11-04). 829 of them (15.8%) were published from 2020 onward, and the busiest period so far is 2000-2009 with 1,962 records.

Reviews account for 210 records (4.0%) and meta-analyses for 5. Randomized controlled trials number 46 (0.9%) as a share of all records on the topic. Randomized trials make up only a small share of this literature, so much of what is known comes from laboratory, observational or descriptive work.

PubMed records by publication periodthrough 1999: 712 records; 2000-2009: 1,962 records; 2010-2019: 1,754 records; 2020 onward: 829 records712through 19991,9622000-20091,7542010-20198292020 onward
Records in PubMed indexed with this heading, by publication period. Real counts from NCBI E-utilities; the final period covers only part of the current year. Volume reflects how much has been published, not how strong the evidence is.
Show the data
PeriodRecords
through 1999712
2000-20091,962
2010-20191,754
2020 onward829
Share of records by publication typeReviews: 4.0 percent; Meta-analyses: 0.1 percent; Randomized controlled trials: 0.9 percentReviews4.0% (210)Meta-analyses0.1% (5)Randomized controlled trials0.9% (46)
Share of all PubMed records on this heading that carry each publication type. Types overlap with other records, so the shares do not sum to 100%.
Publication-type chart data
Publication types among 5,257 PubMed records
TypeRecordsShare
Reviews2104.0%
Meta-analyses50.1%
Randomized controlled trials460.9%

Method: PubMed query "Echo-Planar Imaging"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.

Reading the evidence in diagnostics and medical technology

A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.

Evidence from open-access studies

These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.

Study comparison — selected abstracts, not a systematic review
Study / authorsYearSource label / designEurope PMC citationsLicence / source
Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data
Andersson JLR, Graham MS, Drobnjak I, Zhang H, Campbell J
2018Research article
Design not recorded in structured metadata
155cc by
PMID 29277648 · DOI · PMC5883370
Spin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart
von Deuster C, Stoeck CT, Genet M, Atkinson D, Kozerke S
2016Research article
Design not recorded in structured metadata
60cc by
PMID 26445426 · DOI · PMC4989478
Resolving relaxometry and diffusion properties within the same voxel in the presence of crossing fibres by combining inversion recovery and diffusion-weighted acquisitions
De Santis S, Barazany D, Jones DK, Assaf Y
2016Research article
Design not recorded in structured metadata
58cc by
PMID 25735538 · DOI · PMC4737246
Water/Fat Separated Echo Planar Time-Resolved Imaging (WFS-EPTI) for Distortion-Free Multi-Contrast MRI
Hu Z, Reese TG, Wald LL, Polimeni JR, Dong Z, Wang F
2026Research article
Design not recorded in structured metadata
0cc by
PMID 41955571 · DOI · PMC13269247

Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data [1]

Research article Andersson JLR, Graham MS, Drobnjak I, Zhang H, Campbell J · · 2018 · cited 155 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
Because of their low bandwidth in the phase-encode (PE) direction, the susceptibility-induced off-resonance field causes distortions in echo planar imaging (EPI) images.
Closing excerpt
The results show that we are able to track the field with high accuracy and that we are able to correct the data for the adverse effects of the changing field.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (284 words)

Because of their low bandwidth in the phase-encode (PE) direction, the susceptibility-induced off-resonance field causes distortions in echo planar imaging (EPI) images. It is therefore crucial to correct for susceptibility-induced distortions when performing diffusion studies using EPI. The susceptibility-induced field is caused by the object (head) disrupting the field and it is typically assumed that it remains constant within a framework defined by the object, (i.e. it follows the object as it moves in the scanner). However, this is only approximately true. When a non-spherical object rotates around an axis other than that parallel with the magnetic flux (the z-axis) it changes the way it disrupts the field, leading to different distortions. Hence, if using a single field to correct for distortions there will be residual distortions in the volumes where the object orientation is substantially different to that when the field was measured. In this paper we present a post-processing method for estimating the field as it changes with motion during the course of an experiment. It only requires a single measured field and knowledge of the orientation of the subject when that field was acquired. The volume-to-volume changes of the field as a consequence of subject movement are estimated directly from the diffusion data without the need for any additional or special acquisitions. It uses a generative model that predicts how each volume would look predicated on field change and inverts that model to yield an estimate of the field changes. It has been validated on both simulations and experimental data. The results show that we are able to track the field with high accuracy and that we are able to correct the data for the adverse effects of the changing field.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 29277648 · DOI · PMC5883370

Spin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart [2]

Research article von Deuster C, Stoeck CT, Genet M, Atkinson D, Kozerke S · · 2016 · cited 60 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
PurposeTo compare signal-to-noise ratio (SNR) efficiency and diffusion tensor metrics of cardiac diffusion tensor mapping using acceleration-compensated spin-echo (SE) and stimulated echo acquisition mode (STEAM) imaging.
Closing excerpt
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (264 words)

PurposeTo compare signal-to-noise ratio (SNR) efficiency and diffusion tensor metrics of cardiac diffusion tensor mapping using acceleration-compensated spin-echo (SE) and stimulated echo acquisition mode (STEAM) imaging.MethodsDiffusion weighted SE and STEAM sequences were implemented on a clinical 1.5 Tesla MR system. The SNR efficiency of SE and STEAM was measured (b = 50-450 s/mm(2) ) in isotropic agar, anisotropic diffusion phantoms and the in vivo human heart. Diffusion tensor analysis was performed on mean diffusivity, fractional anisotropy, helix and transverse angles.ResultsIn the isotropic phantom, the ratio of SNR efficiency for SE versus STEAM, SNRt (SE/STEAM), was 2.84 ± 0.08 for all tested b-values. In the anisotropic diffusion phantom the ratio decreased from 2.75 ± 0.05 to 2.20 ± 0.13 with increasing b-value, similar to the in vivo decrease from 2.91 ± 0.43 to 2.30 ± 0.30. Diffusion tensor analysis revealed reduced deviation of helix angles from a linear transmural model and reduced transverse angle standard deviation for SE compared with STEAM. Mean diffusivity and fractional anisotropy were measured to be statistically different (P ConclusionCardiac DTI using motion-compensated SE yields a 2.3-2.9× increase in SNR efficiency relative to STEAM and improved accuracy of tensor metrics. The SE method hence presents an attractive alternative to STEAM based approaches. Magn Reson Med 76:862-872, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 26445426 · DOI · PMC4989478

Resolving relaxometry and diffusion properties within the same voxel in the presence of crossing fibres by combining inversion recovery and diffusion-weighted acquisitions [3]

Research article De Santis S, Barazany D, Jones DK, Assaf Y · · 2016 · cited 58 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
PurposeA comprehensive image-based characterization of white matter should include the ability to quantify myelin and axonal attributes irrespective of the complexity of fibre organization within the voxel.
Closing excerpt
Further the enhanced specificity should ultimately lead to earlier diagnosis and access to treatment in a range of white matter diseases where axons are affected.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (192 words)

PurposeA comprehensive image-based characterization of white matter should include the ability to quantify myelin and axonal attributes irrespective of the complexity of fibre organization within the voxel. While progress has been made with diffusion MRI-based approaches to measure axonal morphology, to date available myelin metrics simply assign a single scalar value to the voxel, reflecting some form of average of its constituent fibres. Here, a new experimental framework that combines diffusion MRI and relaxometry is introduced. It provides, for the first time, the ability to assign to each unique fibre system within a voxel, a unique value of the longitudinal relaxation time, T1, which is largely influenced by the myelin content.MethodsWe demonstrate the method through simulations, in a crossing fibres phantom, in fixed brains and in vivo.ResultsThe method is capable of recovering unique values of T1 for each fibre population.ConclusionThe ability to extract fibre-specific relaxometry properties will provide enhanced specificity and, therefore, sensitivity to differences in white matter architecture, which will be invaluable in many neuroimaging studies. Further the enhanced specificity should ultimately lead to earlier diagnosis and access to treatment in a range of white matter diseases where axons are affected.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 25735538 · DOI · PMC4737246

Water/Fat Separated Echo Planar Time-Resolved Imaging (WFS-EPTI) for Distortion-Free Multi-Contrast MRI [4]

Research article Hu Z, Reese TG, Wald LL, Polimeni JR, Dong Z, Wang F · · 2026

Abstract reading summary — source excerpts
Opening excerpt
PurposeEcho-planar time-resolved imaging (EPTI) provides distortion- and T2/T2* blurring-free multi-echo/multi-contrast imaging with fast speed, making it an efficient acquisition method for various MRI applications.
Closing excerpt
ConclusionThe proposed WFS-EPTI can provide water/fat separation in rapid acquisition and obtain high resolution, distortion-free multi-contrast/quantitative imaging in the presence of fat signals.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (232 words)

PurposeEcho-planar time-resolved imaging (EPTI) provides distortion- and T2/T2* blurring-free multi-echo/multi-contrast imaging with fast speed, making it an efficient acquisition method for various MRI applications. Here, we aim to achieve water-fat separation for EPTI to improve fat signal removal for brain/body imaging applications.Theory and methodsA water/fat separated EPTI (WFS-EPTI) technique is developed, which leverages the intrinsic multi-echo data provided by EPTI readout and introduces a novel strategy for highly-accelerated spatiotemporal encoding and reconstruction to separate water and fat signals. Specifically, DIXON encoding is integrated into the spatiotemporal acquisition by acquiring the echo train at scheduled TEs and echo-spacing, therefore modulating the rapidly changing fat phase evolution across EPTI readout into a more uniform, coherent manner (e.g., in-phase and out-of-phase conditions for odd and even image series). This enables robust subspace representations even in the presence of fat signals. A joint subspace reconstruction is then proposed, which separately performs data consistency for each echo group to ensure fidelity, while jointly leveraging shared information to improve conditioning. Furthermore, an auto-calibrated WFS-EPTI is developed to improve motion robustness for abdominal imaging, and a data-driven basis extraction is employed to address imperfect in-phase/out-of-phase conditions.ResultsBoth phantom experiments and in vivo human imaging across multiple body regions-including brain, head-neck, and abdomen-demonstrated the feasibility of the proposed method.ConclusionThe proposed WFS-EPTI can provide water/fat separation in rapid acquisition and obtain high resolution, distortion-free multi-contrast/quantitative imaging in the presence of fat signals.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 41955571 · DOI · PMC13269247

Key reviews and meta-analyses

The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.

  • Research article Multi-echo fMRI: A review of applications in fMRI denoising and analysis of BOLD signals [5]
    Kundu P, Voon V, Balchandani P, Lombardo MV, Poser BA, Bandettini PA · Neuroimage · 2017 · cited 285 times (Europe PMC)
  • Research article Functional magnetic resonance imaging (FMRI) of the human brain [6]
    DeYoe EA, Bandettini P, Neitz J, Miller D, Winans P · J Neurosci Methods · 1994 · cited 230 times (Europe PMC)
  • Research article Susceptibility-weighted MR imaging: a review of clinical applications in children [7]
    Tong KA, Ashwal S, Obenaus A, Nickerson JP, Kido D, Haacke EM · AJNR Am J Neuroradiol · 2008 · cited 225 times (Europe PMC)
  • Research article Theory and application of static field inhomogeneity effects in gradient-echo imaging [8]
    Reichenbach JR, Venkatesan R, Yablonskiy DA, Thompson MR, Lai S, Haacke EM · J Magn Reson Imaging · 1997 · cited 200 times (Europe PMC)
  • Research article Clinical ultrashort echo time imaging of bone and other connective tissues [9]
    Robson MD, Bydder GM · NMR Biomed · 2006 · cited 147 times (Europe PMC)
  • Research article Echo-planar MR imaging [10]
    Edelman RR, Wielopolski P, Schmitt F · Radiology · 1994 · cited 139 times (Europe PMC)

References

  1. Andersson JLR, Graham MS, Drobnjak I, Zhang H, Campbell J. Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data. . 2018. PMID 29277648 · DOI · PMC5883370
  2. von Deuster C, Stoeck CT, Genet M, Atkinson D, Kozerke S. Spin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart. . 2016. PMID 26445426 · DOI · PMC4989478
  3. De Santis S, Barazany D, Jones DK, Assaf Y. Resolving relaxometry and diffusion properties within the same voxel in the presence of crossing fibres by combining inversion recovery and diffusion-weighted acquisitions. . 2016. PMID 25735538 · DOI · PMC4737246
  4. Hu Z, Reese TG, Wald LL, Polimeni JR, Dong Z, Wang F. Water/Fat Separated Echo Planar Time-Resolved Imaging (WFS-EPTI) for Distortion-Free Multi-Contrast MRI. . 2026. PMID 41955571 · DOI · PMC13269247
  5. Kundu P, Voon V, Balchandani P, Lombardo MV, Poser BA, Bandettini PA. Multi-echo fMRI: A review of applications in fMRI denoising and analysis of BOLD signals. Neuroimage. 2017. PMID 28363836 · DOI
  6. DeYoe EA, Bandettini P, Neitz J, Miller D, Winans P. Functional magnetic resonance imaging (FMRI) of the human brain. J Neurosci Methods. 1994. PMID 7869750 · DOI
  7. Tong KA, Ashwal S, Obenaus A, Nickerson JP, Kido D, Haacke EM. Susceptibility-weighted MR imaging: a review of clinical applications in children. AJNR Am J Neuroradiol. 2008. PMID 17925363 · DOI · PMC8119104
  8. Reichenbach JR, Venkatesan R, Yablonskiy DA, Thompson MR, Lai S, Haacke EM. Theory and application of static field inhomogeneity effects in gradient-echo imaging. J Magn Reson Imaging. 1997. PMID 9090577 · DOI
  9. Robson MD, Bydder GM. Clinical ultrashort echo time imaging of bone and other connective tissues. NMR Biomed. 2006. PMID 17075960 · DOI
  10. Edelman RR, Wielopolski P, Schmitt F. Echo-planar MR imaging. Radiology. 1994. PMID 8058920 · DOI

About this article

Sources
NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
Verification
Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
Review state
automated source verified; no human expert review has been recorded yet.
Version
1, last updated 2026-11-04.

See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.

Evidence strength

EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.

Included with the Researcher plan

Reading every article stays free. This computed view is part of the paid plans.

See plans Sign in

Your notes

Notes and highlights stay in this browser only; they are not sent to EvidenceHelix.

Related research topics

  • Molecular ImagingDiagnostics and Medical Technology
  • Perfusion ImagingDiagnostics and Medical Technology
  • Diffusion Tensor ImagingDiagnostics and Medical Technology
  • Narrow Band ImagingDiagnostics and Medical Technology
  • Magnetic Resonance ImagingDiagnostics and Medical Technology
  • Optical ImagingDiagnostics and Medical Technology

All 110 articles in Diagnostics and Medical Technology →

At a glance

5,257
PubMed records on this heading
16%
published since 2020
210
review articles
46
randomized trials
10
verified references below

Counts come from PubMed on 2026-11-04; they show how much has been written, not how strong the evidence is.

Related topics See all →

  • Molecular ImagingDiagnostics and Medical Technology
  • Perfusion ImagingDiagnostics and Medical Technology
  • Diffusion Tensor ImagingDiagnostics and Medical Technology
  • Narrow Band ImagingDiagnostics and Medical Technology
  • Magnetic Resonance ImagingDiagnostics and Medical Technology

My notes & annotations (0)

Nothing yet. Select text and press Highlight, or write a note in the Notes tab. Stored in this browser only.

Sources

  • NLM MeSH record ↗
  • PubMed search used ↗

EvidenceLib is a research-education resource, not medical advice. It does not diagnose, prescribe or recommend starting, stopping or changing any treatment. Talk to a qualified clinician about your own situation. Methods, sources and licences · Rights and removal requests · Legal · Support