Definition and research guide
This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.
Content available: 4 complete abstracts (1,078 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.
Definition
The determination of oxygen-hemoglobin saturation of blood either by withdrawing a sample and passing it through a classical photoelectric oximeter or by electrodes attached to some translucent part of the body like finger, earlobe, or skin fold. It includes non-invasive oxygen monitoring by pulse oximetry.
Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.
Also known as: Oximetries; Oximetry, Pulse; Oximetries, Pulse; Pulse Oximetries; Pulse Oximetry.
Where it fits in the MeSH classification
- Broader topics
- Blood Gas Analysis; Heart Function Tests
- Narrower topics
- Blood Gas Monitoring, Transcutaneous
Research landscape
PubMed indexes 17,796 records tagged with the MeSH heading “Oximetry” (counts retrieved 2026-11-04). 2,656 of them (14.9%) were published from 2020 onward, and the busiest period so far is through 1999 with 6,346 records.
Reviews account for 1,489 records (8.4%) and meta-analyses for 96. Randomized controlled trials number 1,013 (5.7%) as a share of all records on the topic.
Show the data
| Period | Records |
|---|---|
| through 1999 | 6,346 |
| 2000-2009 | 3,518 |
| 2010-2019 | 5,276 |
| 2020 onward | 2,656 |
Publication-type chart data
| Type | Records | Share |
|---|---|---|
| Reviews | 1,489 | 8.4% |
| Meta-analyses | 96 | 0.5% |
| Randomized controlled trials | 1,013 | 5.7% |
Method: PubMed query "Oximetry"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.
Reading the evidence in diagnostics and medical technology
A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.
Evidence from open-access studies
These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.
| Study / authors | Year | Source label / design | Europe PMC citations | Licence / source |
|---|---|---|---|---|
| Beer-Lambert law for optical tissue diagnostics: current state of the art and the main limitations | 2021 | Review article Design not recorded in structured metadata | 95 | cc by PMID 34713647 · DOI · PMC8553265 |
| Muscle Oximetry in Sports Science: An Updated Systematic Review | 2024 | Systematic review Design not recorded in structured metadata | 65 | cc by PMID 38345731 · DOI · PMC11052892 |
| Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis | 2022 | Meta-analysis Design not recorded in structured metadata | 47 | cc by PMID 35954958 · DOI · PMC9367848 |
| Transcutaneous versus arterial carbon dioxide monitoring in adult polysomnography studies | 2026 | Research article Design not recorded in structured metadata | 3 | cc by PMID 40971476 · DOI · PMC13017198 |
Beer-Lambert law for optical tissue diagnostics: current state of the art and the main limitations [1]
Abstract reading summary — source excerpts
- Opening excerpt
- SignificanceBeer-Lambert law (BLL) is a widely used tool for contact and remote determination of absorber concentration in various media, including living tissues.
- Closing excerpt
- Extended MBLL and BLL in the time domain form could provide more accurate results, but this requires more time resources to be spent.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (280 words)
SignificanceBeer-Lambert law (BLL) is a widely used tool for contact and remote determination of absorber concentration in various media, including living tissues. Originally proposed in the 18th century as a simple exponential expression, it has survived numerous modifications and updates. The basic assumptions of this law may not be fulfilled in real measurement conditions. This can lead to mistaken or misinterpreted results. In particular, the effects to be additionally taken into account in the tissue measurements include anisotropy, scattering, fluorescence, chemical equilibria, interference, dichroism, spectral bandwidth disagreements, stray radiation, and instrumental effects.AimWe review the current state of the art and the main limitations of remote tissue diagnostics using the BLL. Historical development of updating this law by taking into account specific additional factors such as light scattering and photon pathlengths in diffuse reflectance is described, along with highlighting the main risks to be considered by interpreting the measured data.ApproachLiterature data related to extension and modification of the BLL related to tissue assessment and concentration estimation of specific tissue molecules are collected and analyzed. The main emphasis here is put on the optical measurements of living tissue chromophore concentrations and estimation of physiological parameters, e.g., blood oxygen saturation.ResultsModified expressions of the BLL suitable for several specific cases of living tissue characterization are presented and discussed.ConclusionsApplications of updated/modified Beer-Lambert law (MBLL) with respect to particular measurement conditions are helpful for obtaining more reliable data on the target tissue physiological state and biochemical content. MBLL accounting for the role of scattering in several ways appears to be a successful approach. Extended MBLL and BLL in the time domain form could provide more accurate results, but this requires more time resources to be spent.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 34713647 · DOI · PMC8553265
Muscle Oximetry in Sports Science: An Updated Systematic Review [2]
Abstract reading summary — source excerpts
- Opening excerpt
- BackgroundIn the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles.
- Closing excerpt
- Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (324 words)
BackgroundIn the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles.ObjectivesConsidering the consistent number of studies on the application of muscle oximetry in sports science published over the last 5 years, the objectives of this updated systematic review were to highlight the applications of muscle oximetry in the assessment of skeletal muscle oxidative performance in sports activities and to emphasize how this technology has been applied to exercise and training over the last 5 years. In addition, some recent instrumental developments will be briefly summarized.MethodsPreferred Reporting Items for Systematic Reviews guidelines were followed in a systematic fashion to search, appraise and synthesize existing literature on this topic. Electronic databases such as Scopus, MEDLINE/PubMed and SPORTDiscus were searched from March 2017 up to March 2023. Potential inclusions were screened against eligibility criteria relating to recreationally trained to elite athletes, with or without training programmes, who must have assessed physiological variables monitored by commercial oximeters or NIRS instrumentation.ResultsOf the identified records, 191 studies regrouping 3435 participants, met the eligibility criteria. This systematic review highlighted a number of key findings in 37 domains of sport activities. Overall, NIRS information can be used as a meaningful marker of skeletal muscle oxidative capacity and can become one of the primary monitoring tools in practice in conjunction with, or in comparison with, heart rate or mechanical power indices in diverse exercise contexts and across different types of training and interventions.ConclusionsAlthough the feasibility and success of the use of muscle oximetry in sports science is well documented, there is still a need for further instrumental development to overcome current instrumental limitations. Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 38345731 · DOI · PMC11052892
Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis [3]
Abstract reading summary — source excerpts
- Opening excerpt
- The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health.
- Closing excerpt
- This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (249 words)
The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searched and after assessing eligibility criteria the data were extracted. True-positive, false-positive, true-negative, false-negative, sensitivity and specificity values were extracted or calculated if not presented. Quality of studies was evaluated based on the QUADAS 2 tool. Meta-analysis was performed in MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) and Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK). Ten articles were included for qualitative synthesis and five for meta-analysis. The pooled diagnostic odds ratio for pulse oximeter (PO), electric pulp tester (EPT), cold test (CT) and heat test (HT) was 628.5, 10.75, 17.24 and 3.47, respectively. Pairwise comparison demonstrated a higher pooled mean sensitivity and specificity with PO compared with EPT. Comparison between PO and CT and between PO and HT also demonstrated a higher pooled mean sensitivity and specificity for PO. Summary points on receiver operating characteristic curves confirmed the ability of PO to correctly screen negatives in presenting patients as compared to EPT, CT and HT but no study was rated as good on quality assessment. PO can be considered as the most accurate diagnostic method as compared to EPT, CT and HT. This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 35954958 · DOI · PMC9367848
Transcutaneous versus arterial carbon dioxide monitoring in adult polysomnography studies [4]
Abstract reading summary — source excerpts
- Opening excerpt
- Study objectivesTo determine the accuracy of transcutaneous carbon dioxide measurements using SenTec tcPCO2 during adult polysomnography (PSG) compared to arterial PCO2.
- Closing excerpt
- ConclusionsThe SenTec tcPCO2 electrode was found to be an appropriate alternative to arterial sampling for assessment of arterial carbon dioxide in adult patients in the PSG setting, with no significant difference in tcPCO2 accuracy based on the timing of transcutaneous measurements (up to 2 min) following arterial sampling.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (225 words)
Study objectivesTo determine the accuracy of transcutaneous carbon dioxide measurements using SenTec tcPCO2 during adult polysomnography (PSG) compared to arterial PCO2.MethodsIn consecutive patients having PSG with transcutaneous CO2 (tcPCO2) monitoring using a SenTec monitor, arterial blood gas samples were taken at the beginning and at the end of each sleep study. tcPCO2 measurements recorded at 0, 60, and 120 s after arterial sampling was determined in 51 participants who underwent PSG with tcPCO2 monitoring at the Austin Health Sleep Laboratory (Heidelberg, VIC, Australia) during the period 01/05/22-10/06/22. The mean of differences between arterial carbon dioxide tension (PaCO2) and the predicted value based on tcPCO2 measurements determined at each time point for evening and morning arterial samples.ResultsData were obtained from 37 participants. A statistically significant difference in the tcPCO2 values at the point of arterial sampling was found, with tcPCO2 on average 2.2-2.8 mmHg less than PaCO2 at various timepoints after arterial sampling. The upper limit of measurement accuracy represented a moderate difference (2-4.9 mmHg), within the clinically acceptable range of -7.5 to +7.5 mmHg variation from PaCO2 values.ConclusionsThe SenTec tcPCO2 electrode was found to be an appropriate alternative to arterial sampling for assessment of arterial carbon dioxide in adult patients in the PSG setting, with no significant difference in tcPCO2 accuracy based on the timing of transcutaneous measurements (up to 2 min) following arterial sampling.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 40971476 · DOI · PMC13017198
Key reviews and meta-analyses
The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.
- Research article Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations [5]
- Research article Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications [6]
- Research article Pulse oximetry [7]
- Research article Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review and meta-analysis [8]
- Research article Overnight pulse oximetry for sleep-disordered breathing in adults: a review [9]
- Research article Muscle Oximetry in Sports Science: A Systematic Review [10]
References
- Oshina I, Spigulis J. Beer-Lambert law for optical tissue diagnostics: current state of the art and the main limitations. . 2021. PMID 34713647 · DOI · PMC8553265
- Perrey S, Quaresima V, Ferrari M. Muscle Oximetry in Sports Science: An Updated Systematic Review. . 2024. PMID 38345731 · DOI · PMC11052892
- Patro S, Meto A, Mohanty A, Chopra V, Miglani S, Das A, et al.. Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis. . 2022. PMID 35954958 · DOI · PMC9367848
- Miller KA, Churchward TJ, Tolson J, Ruehland WR, McDonald CF, Worsnop CJ. Transcutaneous versus arterial carbon dioxide monitoring in adult polysomnography studies. . 2026. PMID 40971476 · DOI · PMC13017198
- Chan ED, Chan MM, Chan MM. Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations. Respir Med. 2013. PMID 23490227 · DOI
- Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012. PMID 22467064 · DOI · PMC3391360
- Jubran A. Pulse oximetry. Crit Care. 2015. PMID 26179876 · DOI · PMC4504215
- Thangaratinam S, Brown K, Zamora J, Khan KS, Ewer AK. Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review and meta-analysis. Lancet. 2012. PMID 22554860 · DOI
- Netzer N, Eliasson AH, Netzer C, Kristo DA. Overnight pulse oximetry for sleep-disordered breathing in adults: a review. Chest. 2001. PMID 11502669 · DOI
- Perrey S, Ferrari M. Muscle Oximetry in Sports Science: A Systematic Review. Sports Med. 2018. PMID 29177977 · DOI
About this article
- Sources
- NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
- Verification
- Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
- Review state
- automated source verified; no human expert review has been recorded yet.
- Version
- 1, last updated 2026-11-04.
See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.
Evidence strength
EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.