Definition and research guide
This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.
Content available: 4 complete abstracts (1,145 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.
Definition
Implants used in arthroscopic surgery and other orthopedic procedures to attach soft tissue to bone. One end of a suture is tied to soft tissue and the other end to the implant. The anchors are made of a variety of materials including titanium, stainless steel, or absorbable polymers.
Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.
Also known as: Anchors, Suture; Anchor, Suture; Suture Anchor; Bone Anchors; Anchor, Bone; Anchors, Bone; Bone Anchor.
Where it fits in the MeSH classification
- Broader topics
- Internal Fixators
- See also
- Tenodesis
Research landscape
PubMed indexes 2,567 records tagged with the MeSH heading “Suture Anchors” (counts retrieved 2026-11-04). 662 of them (25.8%) were published from 2020 onward, and the busiest period so far is 2010-2019 with 1,590 records.
Reviews account for 252 records (9.8%) and meta-analyses for 31. Randomized controlled trials number 85 (3.3%) as a share of all records on the topic.
Show the data
| Period | Records |
|---|---|
| through 1999 | 0 |
| 2000-2009 | 369 |
| 2010-2019 | 1,590 |
| 2020 onward | 662 |
Publication-type chart data
| Type | Records | Share |
|---|---|---|
| Reviews | 252 | 9.8% |
| Meta-analyses | 31 | 1.2% |
| Randomized controlled trials | 85 | 3.3% |
Method: PubMed query "Suture Anchors"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.
Reading the evidence in diagnostics and medical technology
A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.
Evidence from open-access studies
These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.
Ten years of experience with the Ponto bone-anchored hearing system-A systematic literature review [1]
Abstract reading summary — source excerpts
- Opening excerpt
- BackgroundBone-anchored hearing systems (BAHSs) are widely used for hearing rehabilitation and are indicated in cases of conductive and mixed hearing loss and in single-sided deafness.
- Closing excerpt
- Skin-related complications are the most common complication type and are experienced by approximately one patient out of seven, or in less than one of 20 follow-up visits.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (327 words)
BackgroundBone-anchored hearing systems (BAHSs) are widely used for hearing rehabilitation and are indicated in cases of conductive and mixed hearing loss and in single-sided deafness. The Ponto system, that is one available option, has been on the market since 2009.Objective of reviewThe aim of this study is to systematically review the literature reporting on the Ponto system, with regard to audiological and surgical outcomes and patient's quality-of-life scores.Type of reviewA systematic literature search was performed in the PubMed database 2009-July 2019.Search strategySearch term: ((osseointegrated hearing aid) OR (bone conduction implant) OR (bone anchored hearing) OR BAHA OR BAHS OR BAHI). Pre-defined inclusion and exclusion criteria were applied.Evaluation methodEnglish-language articles reporting original clinical data (audiological, surgical or quality-of-life outcomes) on the Ponto system were included. Articles reporting on Ponto and another BAHS system where the results on Ponto constituted less than 50% of the patient population or including only results on testband or softband devices were excluded.ResultsAudiological outcomes were discussed in 20 publications. Improvement against the unaided thresholds was demonstrated. The functional improvement was on average 33.9 dB. The effective gain or remaining air-bone gap was on average 6.7 dB. All evaluated data showed aided speech reception thresholds significantly below normal speech level. Twenty-seven publications reported surgical and follow-up data for the Ponto system. Implant survival was 97.7%, adverse skin reactions (Holgers ≥ 2) were 5% across visits and 15% across patients. No complications were life-threatening, causing permanent disability/damage or requiring a hospitalisation. Five studies reported quality of life using the Glasgow benefit inventory, 98% reported an improvement when analysing the score on an individual level.ConclusionsThe outcomes of this systematic review confirm that percutaneous systems provide consistent audiological benefits and improved quality of life for patients. Further, the review demonstrates that the percutaneous systems are safe, with relatively low complication rates. Skin-related complications are the most common complication type and are experienced by approximately one patient out of seven, or in less than one of 20 follow-up visits.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 32386454 · DOI · PMC7496709
All-suture anchor pullout results in decreased bone damage and depends on cortical thickness [2]
Abstract reading summary — source excerpts
- Opening excerpt
- PurposeTo evaluate the influence of cortical and cancellous bone structure on the biomechanical properties of all-suture and conventional anchors and compare the morphological bone damage after their failure.
- Closing excerpt
- Also, intraoperative decortication should not be performed and cortical thickness should be preoperatively evaluated to decrease the risk of anchor failure.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (328 words)
PurposeTo evaluate the influence of cortical and cancellous bone structure on the biomechanical properties of all-suture and conventional anchors and compare the morphological bone damage after their failure. The hypothesis of the study is that all-suture anchor pullout is less invasive and that the pullout force is influenced by the cortical thickness.MethodsThirty human humeri were biomechanically tested as follows: starting with a load cycle from 20 to 50 N, a stepwise increase of the upper peak force by 0.05 N for each cycle at a rate of 1 Hz was performed. Analysis included maximum pullout strength for three different anchor implantation angles (45°, 90°, 110°) of the two anchor types. After anchor pullout, every sample underwent micro-CT analysis. Bone mineral density (BMD) and cortical thickness were determined at the anchor implantation site. Furthermore, the diameter of the cortical defect and the volume of the bone cavity were identified.ResultsThe maximum pullout strength of all-suture anchors demonstrates a strong correlation to the adjacent cortical thickness (r = 0.82, p ≤ 0.05) with at least 0.4 mm needed to withstand 200 N. No correlation could be seen in conventional anchors. Moreover, no correlation could be detected for local BMD in both anchors. All-suture anchors show a significantly narrower cortical defect as well as a smaller bone cavity following pullout (4.3 ± 1.3 mm vs. 5.3 ± 0.9 mm, p = 0.037; 141 mm3 vs. 212 mm3; p = 0.009). The cortical defect is largest if the anchors are placed at a 45° angle.ConclusionIn contrast to conventional anchors, the pullout force of all-suture anchors depends on the thickness of the humeral cortex. Furthermore, all-suture anchors show a significantly smaller cortical defect as well as decreased bone damage in the case of pullout. Therefore, the clinical implication of this study is that all-suture anchors are advantageous due to their bone preserving ability. Also, intraoperative decortication should not be performed and cortical thickness should be preoperatively evaluated to decrease the risk of anchor failure.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 32333058 · DOI · PMC8225531
Clinical outcomes after treatment of quadriceps tendon ruptures show equal results independent of suture anchor or transosseus repair technique used - A pilot study [3]
Abstract reading summary — source excerpts
- Opening excerpt
- Biomechanical studies have shown the use of suture anchors (SA) to be superior to the traditional transosseous sutures (TS) in the repair of quadriceps tendon rupture (QTR).
- Closing excerpt
- Treatment of quadriceps tendon rupture using suture anchors provides a clinically valid alternative treatment to the gold-standard transosseous suture repair.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (250 words)
Biomechanical studies have shown the use of suture anchors (SA) to be superior to the traditional transosseous sutures (TS) in the repair of quadriceps tendon rupture (QTR). This study aimed to analyze and compare the functional outcomes of patients treated for quadriceps tendon ruptures using suture anchors or transosseous sutures. Patients having undergone suture anchor repair or transosseous suture repair for quadriceps tendon rupture between 2010 and 2015 at one of the two participating hospitals were included. Patients from site A underwent TS repair (TS group) while patients from site B underwent SA repair (SA group). Exclusion criteria included previous or concomitant injuries of the involved knee, penetrating injuries and pre-existing neurological conditions. Clinical outcome was assessed by subjective scores (Lysholm and Tegner Scores, International Knee Documentation Committee (IKDC) Score, Visual Analog Scale (VAS) for pain), quadriceps isokinetic strength testing, Insall-Salvati Index (ISI), and physical examination. Non-parametrical statistical analysis was conducted using the Mann-Whitney U test. Twenty-seven patients were included in the study of which 17 patients (63%) were available for follow-up (SA group: 9, TS group: 8). All patients were male with a mean age of 62.7 (SD: 8.8) and 57.9 (SD: 12.7) years for the SA group and TS group, respectively. The groups did not differ in terms of demographic characteristics. No clinically significant differences were identified between the two groups. There were no re-ruptures in either group. Treatment of quadriceps tendon rupture using suture anchors provides a clinically valid alternative treatment to the gold-standard transosseous suture repair.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 29554109 · DOI · PMC5858832
Engineering a biomimetic multiphasic suture anchor system for enhanced rotator cuff enthesis regeneration [4]
Abstract reading summary — source excerpts
- Opening excerpt
- The rotator cuff plays a vital role in shoulder movement and joint stability.
- Closing excerpt
- Broadly, this platform offers a versatile solution for biointegrative repair strategies across complex soft-to-hard tissue interfaces.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (240 words)
The rotator cuff plays a vital role in shoulder movement and joint stability. Unfortunately, tears at the rotator cuff enthesis are common and frequently lead to retears after surgical intervention, particularly at the suture location and its anchor sites. These failures are typically due to the inability of current surgical treatments to mimic the native tissue complexity and provide the necessary metabolic, bioactive, and biophysical cues for effective enthesis regeneration. In this study, we engineered a biomimetic multiphasic scaffold system (BMS) to integrate with conventional suture anchor systems and deliver spatially organized structural and biological cues to enhance enthesis regeneration. The BMS consists of three distinct phases: Phase 1 features an aligned, nanofibrous decellularized tendon extracellular matrix (dECM) combined with "stiff" methacrylated hyaluronic acid (MeHA); phase 2 incorporates nonaligned, nanofibrous dECM with "soft" MeHA; and phase 3 uses a porous, bioenergetic, citrate-based composite scaffold for bone integration. In vitro, the BMS notably enhanced tenogenic, fibrochondrogenic, and chondrogenic differentiation, facilitating zone-specific rotator cuff enthesis regeneration. Further, in vivo, the BMS promoted successful integrative healing, forming distinct tendon, fibrocartilage, and bone regions at the repair site. This advanced multiphasic scaffold closely replicates native tissue properties, offering a promising strategy to improve rotator cuff repair. Its integration with conventional suture anchors provides an innovative design that enhances mechanical fixation and guides enthesis healing to reduce retear rates. Broadly, this platform offers a versatile solution for biointegrative repair strategies across complex soft-to-hard tissue interfaces.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 42627896 · DOI · PMC13496182
Key reviews and meta-analyses
The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.
- Research article Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review [5]
- Research article A meta-analysis of the complications associated with osseointegrated hearing aids [6]
- Research article A meta-analysis of open versus arthroscopic Bankart repair using suture anchors [7]
- Research article Complications of bioabsorbable suture anchors in the shoulder [8]
- Research article Arthroscopic brostrom technique [9]
- Research article Is double-row rotator cuff repair clinically superior to single-row rotator cuff repair: a systematic review of overlapping meta-analyses [10]
References
- Lagerkvist H, Carvalho K, Holmberg M, Petersson U, Cremers C, Hultcrantz M. Ten years of experience with the Ponto bone-anchored hearing system-A systematic literature review. . 2020. PMID 32386454 · DOI · PMC7496709
- Ntalos D, Huber G, Sellenschloh K, Saito H, Püschel K, Morlock MM, et al.. All-suture anchor pullout results in decreased bone damage and depends on cortical thickness. . 2021. PMID 32333058 · DOI · PMC8225531
- Plesser S, Keilani M, Vekszler G, Hasenoehrl T, Palma S, Reschl M, et al.. Clinical outcomes after treatment of quadriceps tendon ruptures show equal results independent of suture anchor or transosseus repair technique used - A pilot study. . 2018. PMID 29554109 · DOI · PMC5858832
- Li Z, Lee SH, Xu L, Santos M, Lu R, Zhang EY, et al.. Engineering a biomimetic multiphasic suture anchor system for enhanced rotator cuff enthesis regeneration. . 2026. PMID 42627896 · DOI · PMC13496182
- Duquin TR, Buyea C, Bisson LJ. Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review. Am J Sports Med. 2010. PMID 20357403 · DOI
- Kiringoda R, Lustig LR. A meta-analysis of the complications associated with osseointegrated hearing aids. Otol Neurotol. 2013. PMID 23739555 · DOI
- Petrera M, Patella V, Patella S, Theodoropoulos J. A meta-analysis of open versus arthroscopic Bankart repair using suture anchors. Knee Surg Sports Traumatol Arthrosc. 2010. PMID 20237768 · DOI
- Dhawan A, Ghodadra N, Karas V, Salata MJ, Cole BJ. Complications of bioabsorbable suture anchors in the shoulder. Am J Sports Med. 2012. PMID 21856927 · DOI
- Acevedo JI, Mangone P. Arthroscopic brostrom technique. Foot Ankle Int. 2015. PMID 25743426 · DOI
- Mascarenhas R, Chalmers PN, Sayegh ET, Bhandari M, Verma NN, Cole BJ, et al.. Is double-row rotator cuff repair clinically superior to single-row rotator cuff repair: a systematic review of overlapping meta-analyses. Arthroscopy. 2014. PMID 24821226 · DOI
About this article
- Sources
- NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
- Verification
- Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
- Review state
- automated source verified; no human expert review has been recorded yet.
- Version
- 1, last updated 2026-11-04.
See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.
Evidence strength
EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.