Definition and research guide
This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.
Content available: 4 complete abstracts (978 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.
Definition
Cardiac electrical stimulators that apply brief high-voltage electroshocks to the heart. These stimulators are used to restore normal rhythm and contractile function in hearts of patients who are experiencing ventricular fibrillation or ventricular tachycardia (tachycardia, ventricular) that is not accompanied by a palpable pulse. Some defibrillators may also be used to correct certain noncritical dysrhythmias (called synchronized defibrillation or cardioversion), using relatively low-level discharges synchronized to the patient's ECG waveform. (umdns, 2003)
Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.
Also known as: Defibrillator; Stimulators, Electrical, Cardiac, Shock; Electric Shock Cardiac Stimulators; Automated External Defibrillators; Automated External Defibrillator; Defibrillator, Automated External; Defibrillators, Automated External; External Defibrillator, Automated.
Where it fits in the MeSH classification
- Broader topics
- Electrodes
- Narrower topics
- Defibrillators, Implantable
- See also
- Electric Countershock
Related concepts
- Heart
- Ventricular Fibrillation
- Tachycardia
- Ventricular
- Pulse
- Cardioversion
- Umdns
Research landscape
PubMed indexes 23,502 records tagged with the MeSH heading “Defibrillators” (counts retrieved 2026-11-04). 5,141 of them (21.9%) were published from 2020 onward, and the busiest period so far is 2010-2019 with 10,133 records.
Reviews account for 4,272 records (18.2%) and meta-analyses for 349. Randomized controlled trials number 1,151 (4.9%) as a share of all records on the topic.
Show the data
| Period | Records |
|---|---|
| through 1999 | 1,967 |
| 2000-2009 | 6,261 |
| 2010-2019 | 10,133 |
| 2020 onward | 5,141 |
Publication-type chart data
| Type | Records | Share |
|---|---|---|
| Reviews | 4,272 | 18.2% |
| Meta-analyses | 349 | 1.5% |
| Randomized controlled trials | 1,151 | 4.9% |
Method: PubMed query "Defibrillators"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.
Reading the evidence in diagnostics and medical technology
A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.
Evidence from open-access studies
These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.
Sudden cardiac death after myocardial infarction: individual participant data from pooled cohorts [1]
Abstract reading summary — source excerpts
- Opening excerpt
- Background and aimsRisk stratification of sudden cardiac death after myocardial infarction and prevention by defibrillator rely on left ventricular ejection fraction (LVEF).
- Closing excerpt
- ConclusionsMore accurate risk stratification for sudden cardiac death and identification of low-risk individuals with severely reduced LVEF or of high-risk individuals with preserved LVEF was not feasible, neither using LVEF nor using other predictors.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (254 words)
Background and aimsRisk stratification of sudden cardiac death after myocardial infarction and prevention by defibrillator rely on left ventricular ejection fraction (LVEF). Improved risk stratification across the whole LVEF range is required for decision-making on defibrillator implantation.MethodsThe analysis pooled 20 data sets with 140 204 post-myocardial infarction patients containing information on demographics, medical history, clinical characteristics, biomarkers, electrocardiography, echocardiography, and cardiac magnetic resonance imaging. Separate analyses were performed in patients (i) carrying a primary prevention cardioverter-defibrillator with LVEF ≤ 35% [implantable cardioverter-defibrillator (ICD) patients], (ii) without cardioverter-defibrillator with LVEF ≤ 35% (non-ICD patients ≤ 35%), and (iii) without cardioverter-defibrillator with LVEF > 35% (non-ICD patients >35%). Primary outcome was sudden cardiac death or, in defibrillator carriers, appropriate defibrillator therapy. Using a competing risk framework and systematic internal-external cross-validation, a model using LVEF only, a multivariable flexible parametric survival model, and a multivariable random forest survival model were developed and externally validated. Predictive performance was assessed by random effect meta-analysis.ResultsThere were 1326 primary outcomes in 7543 ICD patients, 1193 in 25 058 non-ICD patients ≤35%, and 1567 in 107 603 non-ICD patients >35% during mean follow-up of 30.0, 46.5, and 57.6 months, respectively. In these three subgroups, LVEF poorly predicted sudden cardiac death (c-statistics between 0.50 and 0.56). Considering additional parameters did not improve calibration and discrimination, and model generalizability was poor.ConclusionsMore accurate risk stratification for sudden cardiac death and identification of low-risk individuals with severely reduced LVEF or of high-risk individuals with preserved LVEF was not feasible, neither using LVEF nor using other predictors.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 39378245 · DOI · PMC11560274
SGLT2i reduce arrhythmic events in heart failure patients with cardiac implantable electronic devices [2]
Abstract reading summary — source excerpts
- Opening excerpt
- BackgroundSodium glucose cotransporter 2 inhibitors (SGLT2i) represent one of the four pillars of heart failure (HF) pharmacological therapy.
- Closing excerpt
- After SGLT2i therapy initiation, the median number of total arrhythmic episodes significantly decreased from a median of 7 [3;12] to 1 [0;4] (P value ConclusionsIn HFrEF carriers of ICD/CRT-D, the use of SGLT2i resulted in significant reduction of AA and VA events.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (196 words)
BackgroundSodium glucose cotransporter 2 inhibitors (SGLT2i) represent one of the four pillars of heart failure (HF) pharmacological therapy.ObjectiveThe study aims to clarify SGLT2i antiarrhythmic effect on patients with HF with reduced ejection fraction (HFrEF) in terms of atrial and ventricular arrhythmias (AAs and VAs) reduction.MethodsHFrEF carriers of implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) followed by remote monitoring of Policlinico Umberto I of Rome for 1 year before and after SGLT2i therapy initiation were enrolled in the study. We compared the incidence of AAs and VAs as recorded at remote monitoring during 1 year preceding SGLT2i therapy initiation and after 1 year of SGLT2i therapy.ResultsAmong 198 enrolled patients, 135 patients had arrhythmic events before SGLT2i therapy prescription. There were 1353 arrhythmic events recorded in the year before SGLT2i therapy prescription, and 354 events were detected in the year after SGLT2i initiation, with a 73.8% reduction in events number after therapy initiation. After SGLT2i therapy initiation, the median number of total arrhythmic episodes significantly decreased from a median of 7 [3;12] to 1 [0;4] (P value ConclusionsIn HFrEF carriers of ICD/CRT-D, the use of SGLT2i resulted in significant reduction of AA and VA events.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 39921334 · DOI · PMC12055389
Device-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial [3]
Abstract reading summary — source excerpts
- Opening excerpt
- BackgroundThe PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.
- Closing excerpt
- gov; Unique identifier: NCT01296022.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (366 words)
BackgroundThe PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.1 months. Complications associated with transvenous leads are expected to occur after longer follow-up. The PRAETORIAN-XL trial aims to investigate whether the S-ICD is superior to the TV-ICD with respect to device-related complications at 8-year follow-up.MethodsThe PRAETORIAN trial randomized patients with a class I or IIa indication for ICD therapy without the need for pacing to either S-ICD or TV-ICD among 39 centers in the United States and Europe between March 2011 and January 2017. The follow-up was extended after 49.1 months by an additional 4 years for the PRAETORIAN-XL trial. The primary end point was the composite of all device-related complications. Complications could be related or unrelated to the lead and minor or major, with major complications being those requiring an invasive intervention. End points were analyzed according to the modified intention-to-treat principle using a Fine-Gray subdistribution hazards model to account for competing risks. An as-treated analysis was performed using a Cox proportional hazards model with device type as time-dependent variable.ResultsPatients were randomized to S-ICD (n=426) and TV-ICD (n=423). Twenty-one percent of the S-ICD group versus 18% of the TV-ICD group were women. The median age at implantation was 63 (interquartile range, 54-69) years for the S-ICD and 64 (interquartile range, 56-69) years for the TV-ICD. After a median follow-up of 87.5 months, all device-related complications (major and minor combined) were not significantly different in the modified intention-to-treat analysis (subdistribution hazard ratio, 0.73 [95% CI, 0.48-1.12]); P=0.15). However, TV-ICD patients more often had a major complication or lead-related complication (P=0.03 and PP=0.047).ConclusionsThe PRAETORIAN-XL trial demonstrated that there was no significant difference between the S-ICD and TV-ICD in all device-related complications during long-term follow-up. However, the TV-ICD carries a higher risk of major and lead-related complications compared with S-ICD therapy. The S-ICD should therefore be considered for all patients without a pacing indication who are evaluated for ICD therapy.RegistrationURL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 40279654 · DOI · PMC12272918
Wearable Cardioverter-Defibrillator in Adult Congenital Heart Disease: A Bridge to Decision, Recovery, and Advanced Therapies [4]
Abstract reading summary — source excerpts
- Opening excerpt
- Sudden cardiac death (SCD) remains a major cause of mortality among adults with congenital heart disease (ACHD).
- Closing excerpt
- This review summarizes the pathophysiological rationale, available evidence, and potential clinical applications of WCD therapy in ACHD.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (162 words)
Sudden cardiac death (SCD) remains a major cause of mortality among adults with congenital heart disease (ACHD). Risk stratification for malignant ventricular arrhythmias in this population is challenging because of the heterogeneity of anatomical substrates, lifelong haemodynamic changes, and the limited predictive accuracy of currently risk models. Furthermore, implantation of an implantable cardioverter-defibrillator (ICD) in ACHD patients is frequently complicated by anatomical constraints, limited venous access, and a significant burden of device-related complications, including infection involving prosthetic material. Several transient cardiac or systemic conditions-including haemodynamic deterioration, acquired myocardial disease, infections, inflammatory states, pregnancy, endocrine disturbances, or peri-procedural phases-may temporarily increase arrhythmic risk or impair ventricular function. In these scenarios, the indication for permanent ICD may be uncertain or premature. The wearable cardioverter-defibrillator (WCD) provides a non-invasive option for temporary protection against life-threatening ventricular arrhythmias while allowing time for clinical stabilization, diagnostic reassessment, and individualized decision-making. This review summarizes the pathophysiological rationale, available evidence, and potential clinical applications of WCD therapy in ACHD.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 42183941 · DOI · PMC13201283
Key reviews and meta-analyses
The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.
- Research article Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis [5]
- Research article Subclinical device-detected atrial fibrillation and stroke risk: a systematic review and meta-analysis [6]
- Research article Remote Monitoring of Implantable Cardioverter-Defibrillators: A Systematic Review and Meta-Analysis of Clinical Outcomes [7]
- Research article Gender differences in clinical outcome and primary prevention defibrillator benefit in patients with severe left ventricular dysfunction: a systematic review and meta-analysis [8]
- Research article Outcome and complications after implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy: systematic review and meta-analysis [9]
- Research article Effectiveness of prophylactic implantation of cardioverter-defibrillators without cardiac resynchronization therapy in patients with ischaemic or non-ischaemic heart disease: a systematic review and meta-analysis [10]
References
- Peek N, Hindricks G, Akbarov A, Tijssen JGP, Jenkins DA, Kapacee Z, et al.. Sudden cardiac death after myocardial infarction: individual participant data from pooled cohorts. . 2024. PMID 39378245 · DOI · PMC11560274
- Mariani MV, Lavalle C, Palombi M, Pierucci N, Trivigno S, D'Amato A, et al.. SGLT2i reduce arrhythmic events in heart failure patients with cardiac implantable electronic devices. . 2025. PMID 39921334 · DOI · PMC12055389
- Olde Nordkamp LRA, de Veld JA, Ghani A, Kuschyk J, Bonnemeier H, Bode K, et al.. Device-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial. . 2025. PMID 40279654 · DOI · PMC12272918
- Sarubbi B, Murredda A, Ciriello GD, Correra A, Papaccioli G, Colonna D. Wearable Cardioverter-Defibrillator in Adult Congenital Heart Disease: A Bridge to Decision, Recovery, and Advanced Therapies. . 2026. PMID 42183941 · DOI · PMC13201283
- Polyzos KA, Konstantelias AA, Falagas ME. Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis. Europace. 2015. PMID 25926473 · DOI
- Mahajan R, Perera T, Elliott AD, Twomey DJ, Kumar S, Munwar DA, et al.. Subclinical device-detected atrial fibrillation and stroke risk: a systematic review and meta-analysis. Eur Heart J. 2018. PMID 29340587 · DOI
- Parthiban N, Esterman A, Mahajan R, Twomey DJ, Pathak RK, Lau DH, et al.. Remote Monitoring of Implantable Cardioverter-Defibrillators: A Systematic Review and Meta-Analysis of Clinical Outcomes. J Am Coll Cardiol. 2015. PMID 25983009 · DOI
- Santangeli P, Pelargonio G, Dello Russo A, Casella M, Bisceglia C, Bartoletti S, et al.. Gender differences in clinical outcome and primary prevention defibrillator benefit in patients with severe left ventricular dysfunction: a systematic review and meta-analysis. Heart Rhythm. 2010. PMID 20380893 · DOI
- Schinkel AF, Vriesendorp PA, Sijbrands EJ, Jordaens LJ, ten Cate FJ, Michels M. Outcome and complications after implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy: systematic review and meta-analysis. Circ Heart Fail. 2012. PMID 22821634 · DOI
- Theuns DA, Smith T, Hunink MG, Bardy GH, Jordaens L. Effectiveness of prophylactic implantation of cardioverter-defibrillators without cardiac resynchronization therapy in patients with ischaemic or non-ischaemic heart disease: a systematic review and meta-analysis. Europace. 2010. PMID 20974768 · DOI · PMC2963481
About this article
- Sources
- NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
- Verification
- Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
- Review state
- automated source verified; no human expert review has been recorded yet.
- Version
- 1, last updated 2026-11-04.
See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.
Evidence strength
EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.